OPERATING AND MAINTENANCE MANUAL
SWITCHMATIC 2T SERIES CONTROLLER
2. Press
repeatedly until you exit the ADVANCED MENU.
3. Identical start-up and cut-out pressure adjustment on both units.
For optimal synchronization operation, the difference between the start and stop pressures
must be at least 1 bar.
4. Press
to disable this unit. The display will indicate "OFF".
5. Press
again on both devices to activate synchronization.
Note 4: After 10 cycles the unit configured as E01 will display pressure and the unit
configured as E02 will display amps on the display.
13. PRESSURE SENSOR CALIBRATION
In case of an erroneous reading by the sensor, it can be recalibrated. To calibrate the sensor
it is necessary to have a pressure gauge installed. Follow the following steps:
ZERO CALIBRATION
1. Press ENTER
2. Open the taps to have the installation depressurized.
3. Press the buttons
4. Pres
to validate.
SCALE FOUND
1. Start the pump up to the pressure switch cut-off pressure.
2. Press the buttons
3. Adjust the pressure values with the buttons
4. Press
to validate.
Note 5: Pressure sensor decalibration should not be normal. If it happens repeatedly,
contact technical service.