ART
4 X
LITE/G2+
MONITOR
SAFETY PRECAUTIONS
Always disconnect the power supply
-
before installing or making modifications to the device.
.
- The fitting and handling of these devices must be carried out by
.
- The wiring must run at least 40 cm. away from any other wiring.
- Do not overtighten the screws on the connector.
- Install the monitor in a dry protected location free from the risk of dripping or splashing water.
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Before connecting the device to the mains, check the connections between the door panel, power
supply, distributors and monitors.
- Always follow the instructions contained in this manual.
( )
CHARACTERISTICS
*
- Hands-free monitor ("ART 4TH LITE" monitor allow handset communication, too).
- 4,3
" TFT c
olo r
u screen
.
.
-
Function push buttons
for access and selection of menu function
- Monitor
with simple installation (non-polarised 2 wires bus)
- Settings menu (settings see page 3).
.
-
Installer
settings
menu
.
.
-
Output auxiliary call repeater (max.
50mA/12V ).
.
- "HZ" input for calls from apartment front door.
.
- Push buttons for door release 1 and 2.
.
- Push-button LED
blinks indicating "channel busy".
.
-
Configuration switches to assign the
call
address
( )
SYSTEM OPERATION
*
- To make a call, the visitor must press the button of the apartment; an audible sound indicates that the call is
being made and
door panel
LED
will turn on. If vocal synthesis is enabled, a 'Call is in progress'
message appears indicating that a call is being made. At this moment, the apartment's monitors receive
the call. If another apartment is called by mistake, press the button for the correct apartment and the first
call will be cancelled.
- Upon receiving the call, the image will appear on the screen of the master monitor (and slave 1, if it exists)
without the visitor knowing To view the image from slave monitors 2 or 3, press
.
monitor to display the image and the button
seconds,
door panel
LED
will turn off and the system will become free.
- To establish communication, press
the button
turn on.
- Co
mmunication
will last for 90 seconds or until
ends,
door panel
LED
will turn off and the system will become free. If vocal synthesis is enabled, a
'Communication is finished' message will indicate that the call is over.
- I f you wish to open the door, press the push-button
press the push-button
), during the call or communication processes: one press will activate the lock
release for seconds and
3
door panel
LED will also turn on for seconds. If vocal synthesis is enabled, a
'Door open' message will be indicated on the door panel.
is
-
Detailed operation
and configuration
of the monitor
( )
INSTAL A
L TION OF THE
MONITOR
*
( )
*
For more information, see
"TART 4 X
LITE
authorised personnel
.
(see page 3)
.
.
dc
(1 to 128)
and
end of line.
one of the buttons of the
will blink white. If the call is not answered within 45
on monitor
, door panel LED
will turn off and the led
the button
on
monitor is
pressed When communication
.
(if it exists and you wish to open the 2nd door,
3
, see "TART
4 XLITE
/G2+" user manual
.
/G2+
user manual
.
2
ART
4 X
LITE/G2+
( )
DESCRIP
TION
MONITOR
*
A
B
J
G
SA
GND
H
HZ
HZ
BUS
BUS
I
128
codes
SA
DIP 1 to 7
GND
Monitor
address
HZ
DIP 8
HZ
EOL
resistor
BUS
OFF = 0
ON = 1
J
BUS
( )
*
Monitor address (code) setup:
Dip1 Dip7:
-
Sets the monitor address (addresses to
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
monitor code is the sum of the values of the switches set to ON.
Important: Apartment 1 (Dip1 to ON & Dip2-Dip to OFF)
Important: Apartment 2 (Dip1 - Dip to OFF).
1 8
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable ends.
Deactivate it only in intermediate monitors.
will
Not : e To define whether the monitor is master
Dip1 to Dip : 7 These assign the address of the monitor to call button on the door panel.
Switches - must remain in the OFF position.
2 7
Apartment 1
ON
1
2
3
4
5
6
7
8
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitor
where the bus cable ends. Deactivate it only in intermediate monitors.
Dip 8
to
ON
ON
1
2
3
4
5
6
7
8
( )
*
For more information, see
EN
MONITOR
A. Spea er.
k
B. Function buttons, access and selection of menu functions.The function
*
buttons in a menu will be illuminated and the function is shown on the
monitor screen with an icon located just above each function button (see
manual "TART 4 XLITE/G2+").
With standby monitor:
C
One press accesses the settings menu call tone volume, call tone selection
and activate/deactivate call tone for 45 sec.
One press accesses the intercom menu in the same apartment and the
guard unit (if installed).
5 quick presses accesses the installer menu the screen settings menu.
D
One press starts the auto-on function on door panel 1.
One press activates "staircase light" (requires SAR-G2+ and SAR-12/24).
E
Press to access 'Doctor mode' function (standby monitor):
*
- With the special code '0441' (Doctor mode) already entered (see special
F
codes i
n manual "TART 4 XLITE/G2+"
activate the function (the display will show the icon
the function press the button for 5 seconds (the display will show the
icon
).
J
- The LED on the push button
"Automatic door opening" is activated and will turn off if the function is
deactivated.
C. 4.3" TFT colour screen.
D. Not used.
E. Microphone.
F. Raised dots for the visually impaired people.
In call
/ com unica
m
tion:
Above this raised dot is the 'Start/ nd communication' button.
E
Above these raised dots is the 'Door opening' button.
G. Configuration switches.
J
H.
Installation terminals
.
I.
Golmar Use.
J. Wall mounting connector fixing (x4).
Building / Villa (Nexa Door Panel)
1
1 8
2
).
Table of values
7
.
Switch number:
1 2 3 4 5
7
Value when ON
:1 2 4 8 16 32 64
Dip 8 a ON
Dip 8 a OFF
ON
ON
1
2
3
4
5
6
7
8
1
2
3
4
("MI" factory default)
or slave ,
1 slave 2 or slave 3.
Villa (Soul Door Panel)
*
Not : e To define whether the monitor is master ("MI" factory
default)
or slave ,
1 slave 2 or slave 3.
Dip 8
to
OFF
ON
1
2
3
4
5
6
7
8
"TART 4 X
LITE
/G2+
user manual
".
3
&
), press the button for 1 sec.
0
to
), to deactivate
will flash white if the function
ON
6
7
1
2
3
4
5
6
7
8
Example: 0+ 0+4+0+ 16+
0+0
= 20
5
6
7
8
*
Manual
Kit Soul / Art 4 XLite
EN