FOR ALTERNATIVE PIPING METHODS TO CONNECT THE
APPLIANCE TO THE GAS SUPPLY, A TRAINED SERVICE MAN
OR GAS APPLIANCE INSTALLER MUST MAKE THE GAS SUPPLY
CONNECTION.
Leak testing of the appliance shall be conducted by the Installer
according to the Instructions given.
Unless prohibited by local codes or ordinances, a new A.G.A.
- Certified, flexible metal appliance connector may be used to
connect this appliance to its gas supply.
The connector must have an internal diameter not less than
nominal 1/2" NPT pipe and be no more than 5 feet in length.
A 1/2" NPT x 1/2" flare union adapter is required at each
end of the flexible connector.
If a flexible connector is used assure that both the appliance
pressure regulator and manual shut-off valve are joined
solidly to other permanent hard piping (either gas supply or
the appliance manifold) so as to be physically stationary. See
figure.
CAUTION
Do not attempt to attach the flexible connector directly to an
external pipe thread.
Connection requires flare union adapters.
For Massachusetts Installations:
1. Shut-off valve must be a "T" handle gas cock.
2. Flexible gas connector must not be longer than 36 inch.
3. Not approved for installation in a bedroom or a bathroom
unless unit is direct vent.
GASKET
FLARE UNION
ADAPTOR
APPLIANCE
PRESSURE
REGULATOR,
SUPPLIED (OBSERVE
DIRECTIONALITY
OF GAS FLOW)
FLARE
UNION
ADAPTOR
FLEXIBLE
APPLIANCE
PRESSURE REGULATOR,
CONNECTOR
(
5 FT. MAX
)
(1.52 m) MAX
FLARE
UNION
ADAPTOR
GAS
SHUT-OFF
VALVE
1/2" NPT PIPE
(STATIONARY
SUPPLY PIPE)
NO APPLIANCE
MOUNTED BELOW
THIS COOKTOP
MANIFOLD
ENTRANCE
FLARE
UNION
ADAPTOR
GASKET
1/2" NPT
PIPE NIPPLE
ELBOW
FLEXIBLE
APPLIANCE
CONNECTOR
(
5 FT. MAX
)
(1.52 m) MAX
FLARE
UNION
ADAPTOR
APPLIANCE
SUPPLIED (OBSERVE
DIRECTIONALITY
OF GAS FLOW)
1/2" NPT
PIPE NIPPLE
GAS
SHUT-OFF
VALVE
1/2" NPT PIPE
(STATIONARY
SUPPLY PIPE)
WALL OVEN MOUNTED
IN CABINETRY BELOW
THIS COOKTOP
EN