BEFORE INSTALLATION
3.
Upon receipt of this device, check for damage to the packaging or product.
DO NOT PROCEED with installation if any damage is found; contact your supplier. Do not use
extension leads with the device. This can pose a danger particularly in the vicinity of a swimming
Make sure the place you choose for installation meets the following conditions:
- Ambient temperature from -10~40℃
- 45 to 90 percent relative humidity, non-condensing
- Less than 1000m above sea level
- Keep out of direct sunlight
- Good ventilation
For efficient cooling, please make sure it is installed with a minimum clearance surrounding it (Fig.2)
Blocked ventilation or an enclosed space with limited air flow may cause overheating or potential
operational failure of the inverter.
4. CONNECTING TO POOL PUMP
Please follow these steps and the wiring diagram for correct connection. The warranty may be
compromised if the device is not installed in accordance with instructions described in this manual.
Only ONE pump can be connected to the inverter. Please do not connect any other appliance to the
output.
Mark the hole locations on the wall, drill and insert the expansion plugs supplied, fit the screws and hang
the device on the screws.
4.1 Turn off all electrical supply to the pool pump, unplug it from the main switch or at the chlorinator which
provides electrical power to the pump.
4.2 Plug the pool pump into the device's power outlet (marked PUMP CONNECTION ONLY). It is
recommended that the total length of the output cable of the device and the power cable of the pool
pump shall not exceed 2m.
4.3 Plug the device into the main switch/chlorinator/timer connection where the pump was originally
plugged into.
4.4 In order to reduce the impact of electromagnetic interference, please connect the grounding wire on the
device to the ground terminal of the pool pump motor(It's not necessary to connect it if there is no plug
min. 25cm
4
min. 40cm
Fig.2