trapped.
 If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
 Please according to local regulations regarding disposal of the appliance for its flammable
blowing gas. Before you scrap the appliance, please take off the doors to prevent children
trapped.
 This appliance is intended to be used in household and similar applications such as
- staff kitchen areas in shops, offices and other working environments;
- farm houses and by clients in hotels, motels and other residential type environments;
- Catering and similar non-retail applications.
 The appliance shall not be installed in public corridors or lobbies.
 The appliance is to be installed in accordance with the Safety Standard for Refrigeration
Systems, ANS\/ASHRAE 15.
 Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp
edges, or any other adverse environmental effects. The check shall also take into account the
effects of aging or continual vibration from sources such as compressors or fans.
 Before carrying out Decommissioning procedure, it is essential that the technician is
completely familiar with the equipment and all its detail. It is recommended good practice that
all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant
sample shall be taken in case analysis is required prior to re-use of recovered refrigerant. It is
essential that electrical power is available before the task is commenced.
 When removing refrigerant from a system, either for servicing or decommissioning, it is
recommended good practice that all refrigerants are removed safely.
 The recovery equipment shall be in good working order with a set of instructions concerning
the equipment that is at hand and shall be suitable for the recovery of all appropriate
refrigerants including, when applicable, FLAMMABLE REFRIGERANTS
 The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery
cylinder, and the relevant waste transfer note arranged. Do not mix refrigerants in recovery
units and especially not in cylinders
 The maximum loading of each type of shelf is 30kg.
 All maintenance staff and others working in the local area shall be instructed on the nature of
work being carried out. Work in confined spaces shall be avoided.
 If any hot work is to be conducted on the refrigerating equipment or any associated parts,
appropriate fire extinguishing equipment shall be available on hand. A dry chemical or CO2 fire
extinguisher should be adjacent to the charging area.
 No person carrying out work in relation to a REFRIGERATING SYSTEM which involves exposing
any pipe work shall use any sources of ignition in such a manner that it may lead to the risk of
fire or explosion. All possible ignition sources, including cigarette smoking, should be kept
sufficiently far away from the site of installation, repairing, removing and disposal,during
which refrigerant can possibly be released to the surrounding space. Prior to work taking pl ace,
the area around the equipment shall be surveyed to make sure that there are no flammable
hazards or ignition risks."No Smoking" signs shall be displayed.
 Checking for presence of refrigerant, The area shall be checked with an appropriate refrigerant
detector prior to and during work, to ensure the technician is aware of potentially toxic or
flammable atmospheres. Ensure that the leak detection equipment being used is suitable for
use with all applicable refrigerants, i.e., no spark, adequately sealed, or intrinsically safe.
 Ensure that the area is in the open or that it is adequately ventilated before breaking into the
system or conducting any hot work. A degree of ventilation shall continue during the period
that the work is carried out. The ventilation should safely disperse any released refrigerant and
preferably expel it externally into the atmosphere.