EN
203 Route de Grenoble
69805 SAINT PRIEST
France
Serial number : V350A - 50000 ' 51000
complies to the provision of the "machinery directive" 2006/42/EC, also complies with the provisions of the
"noise emission by equipment for use outdoors" 2000/14/EC procedure applied for the conformity assessment :
This CE certification applies exclusively to the equipment and does not include any hydraulic, electrical or
Information contained in this manual is not contractual.
Instructions concern regular maintenance only.
It is forbidden to carry out any modification whatsoever on equipment.
Only use original parts.
SAFETY PRECAUTIONS
The operator should be fully aware of the contents of this manual.
This manual must be available to the operator at all times.
Furthermore, it is essential to be informed of and comply with local regulations concerning hydraulic rock breakers and their use.
MOUNTING ON CARRIER
The operator must comply with the "Instructions for use" contained in this manual, as well as those concerning the carrier, such as carrier
weight, pressure, flow and connections.
Before any operation is carried out on the equipment, ensure that decompression and cooling in the hydraulic circuit and mechanical parts
has been completed and avoid loss of any oil.
Ensure that all hydraulic components are conform with standards in force.
ENERGY CHAMBER
The breaker contains an energy chamber containing pressurized nitrogen.
All operations carried out on the hydraulic rock breaker must begin by the decompression of the nitrogen (See "Workshop manual").
USE
The operating zone must be made secure and well- lit.
If the carrier is operating in an area where there is a risk of falling objects, the cabin should be equipped with an approved FOPS protection
system.
Before starting work the operator must inquire about the presence of electric cables, gas or water pipelines, and any other possible source
of danger in the operating zone.
If the carrier has no cabin, it is highly recommended to provide a protective grid at the front of the carrier and reduce emission of dust (water
spray...).
The use of a hydraulic rock breaker without tool retaining pins is strictly forbidden.
Beware : The vibrations of the breaker in operation exceed 2.5 m/s2, all contact with the body of the breaker must be avoided.
86716891
EC DECLARATION OF CONFORMITY
Declare that the machine described below
Hydraulic rock breakers
V3500 - V4500
V450D- 50000 ' 51000
internal control of production (Annex 5).
mechanical adaptation carried out by the installator.
Issued at Saint- Priest, on 01/07/2013, by J.S. COMARMOND,
Director of Engineering
- measured : dB LwA
- guaranteed : dB LwA
4
2013
Noise level
V3500
V4500
123
123
126
126