INSTALLATION INSTRUCTIONS
C-BD-A-PWY Series
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou votre
code électrique local. Si vous n'êtes pas familier avec ces
codes et ces exigences, veuillez contacter un électricien
qualifié.
3.
Suitable for Wet Locations.
Adspte pour les Endroits Mouiles.
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
NOTES
1. This carton contains fixture, anchor bolts and mounting
template. See reverse side for not-to-scale mounting
template.
FOUNDATION
1.
Foundation should be a minimum of 12 inches (305 mm) in diam-
eter, finished level and smooth, with a depth below grade of 24 (610
mm) inches. NOTE: in areas where frost is imminent, consult with a
civil engineer for a recommended foundation detail.
2.
Provided are three 3/8" diameter x 11" (352 mm) long anchor bolts
and mounting template (included). Use template to set anchor bolts
at proper location (Note conduit entry allowance). Anchor bolts
should project 2" (51 mm) above concrete.
following:
www.e-conolight.com
Document:
LPN05501X0001A0_A
Created By:
TMT
BOLLARD INSTALLATION
NOTE: Lens assembly does not need to be removed from
bollard pole during installation process.
1.
To install bollard pole to anchor bolts, loosen three #8 Phillips screws
at the base of the pole using a Phillips screw driver. See Figure 1.
2.
Begin lifting pole and lens assembly vertically off base. When wiring
quick disconnect is exposed, unlatch two halves of quick disconnect
and set pole/lens assembly aside. See Figure 2.
3.
Adjust the CCT and wattage settings.
4.
Install base plate and inner frame assembly over anchor bolts and
secure with nuts, washers, and jam nuts provided.
NOTE: If leveling of the base is required, leveling nuts should be
used. Do NOT use shims.
5.
Make electrical supply connections to terminal block on inner frame
assembly. See Electrical Connection section for proper wiring.
6.
Reconnect two halves of quick disconnect from Step 2 and slide pole/
lens assembly over interior frame and base. Be careful not to pinch
any lead wires. See Figure 3 on back page.
NOTE: Position pole so that the #8 Phillips screws align with circular
indentations in base.
7.
Tighten the three #8 Phillips screws to secure pole/lens assembly to
base.
8.
With the supply power off, unscrew the photocontrol and carefully
adjust the switch on the back side to enable or disable the
photocontrol. Take care not to pull, pinch, or disconnect the harness
wires.
FIGURE 1
FIGURE 2
|
888.243.9445
|
FAX: 262.504.5409
Date