Item:
OS-PIR-12V
OS-PIR-BT-12V
PROGRAMMING INSTRUCTIONS
Parameter Setting By Remote Control:
Note: Factory default settings are as follows: 100% brightness, 100% sensitivity, 5 minute hold time, disabled daylight
sensor, 30% stand-by level and 30 minute stand-by time.
Mode Setting:
1. Press MODE1 on the remote.
2. Press the up or down arrow to enable editing and to select the parameter to be changed.
3. Once all the parameters have been set to the desired values, press OK to save.
4. Press Mode1 to verify the changes have been saved. Press OK.
5. Standing under a powered-on light, aim the remote at the sensor and press the AUTO button. The light will flash off and
on to confirm.
6. Press MODE1 and once again aim the remote at the sensor. Press SEND. The light will flash off and on to confirm.
Note: Up to 4 modes can be stored in the remote. Follow the steps above 3 more times selecting a different mode each
time.
www.topaz-usa.com | 800.666.2852 | ©2023 Southwire Company, LLC. All rights reserved.
PIR MOTION SENSOR
Description
Button
Description
Button