Descargar Imprimir esta página

Safire SAF 001G Manual Del Operador página 7

Horno a gas

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
MAINTENANCE
1.
The flame should be blue and can have orange tips If the flame is yellow it could be an
obstruction in the venturi tube or the jet is not securely Fitted. If the jet gets blocked replace it
do not clean it as this could damage the jet
2.
When replacing the jet, do not over tighten the jet
3.
If there is a problem with your regulator it must be replaced
4.
Food produces flammable fats and juices ensure to keep you SAfire clean at all times
5.
When washing your SAfire , using the extra dome nut supplied screw on the extra dome
nut supplied (hand tight) over the Jet this will prevent dirty water getting into your jet and
blocking it
6.
When replacing the top plate and ventur tube, insure the tube is correctly seated over the gas
valve
(See figure 3)
7.
When storing your SAfire for a long period of time coat the whole unit with a fine film of
Vegetable oil do not put oil into or on the jet
SPECIFICATIONS
CAUTION FOR OUTDOOR USE ONLY - READ INSTRUCTIONS BEFORE USE
WARNING: ACCESSIBLE PARTS MAY BE VERY HOT. KEEP YOUNG CHILDREN AWAY
Product
Outdoor Gas BBQ Roaster
Model
SAF 001G
Gas Type Propane
LPG
Butane at 28-30 mba
Rated presure
propane at 37 mbar
Propane at 37 mbar
Country
BE-FR-IT-LU-IE-GB-GR
PT-ES-CY-CZ-LT-SK-CH
SI-LV
Jet Size/injector size
0.48mm
Heat Input
1kW(73g/h)
Made in India under licence to SAfire Cookers ( pty) LTD
SAF 001 G
LPG
30 mbar
LU-NL-DK-FI-SE-CY-CZ
EL-LT-MT-SK-SI-BG-IS
NO-TR-HR-RO-IT-HU-LV
0.48mm
1kW(73g/h)
xxxx-yy
Pin No. 0359CR00674
SAF 001 G
LPG
50 mbar
DE-AT-CH-SK
0.42mm
1kW(73g/h)
ENGLISH

Publicidad

loading

Este manual también es adecuado para:

916612