SYSTEM INSTALLATION
10. INSTALLATION WARNINGS
The water source must be disconnected
electrically during the entire installation.
DO NOT turn on the hot water switch until the
second lling is done to avoid breakage in the
resistor.
DO NOT turn on the cold water switch if not
needed. Every time you need to turn off the
equipment, please wait at least 3 minutes to
reconnect it. That way you can protect the
compressor from any possible damage.
Water temperature setting:
The temperature is set at 5 ° C. You can change
the cooling temperature from the cold water
regulator. If you turn the screw clockwise, the
water will get cooler.
11. SYSTEM INSTALLATION (REVERSE OSMOSIS)
1.
You will need a pressure pump if the pressure is
not at least 3 Kg / cm
2
2.
Please make sure to install the device in a
drinking water inlet and at room temperature.
3.
Install a water inlet tap to perform maintenance.
4.
Connect the input key to the source through the
¼" tubing. The input connection is indicated on
the device.
5.
Now connect the drain to the outlet marked
through the ¼" tubing.
6.
Disconnect the output of the activated carbon
filters and the water inlet to the system. To do
this you will need to remove the front cover. Plug
the machine into the electrical system and open
the stopcock. Wash the activated carbon filters
with tap water for 5 minutes until the water is
clear.
7.
Now, reconnect the carbon filter socket to the
membrane
holder
inlet.
stopcock and ensure that there are no leaks and
that there is osmotic water production while
pressing the cold water button.
.
Open
the
water
8.
Place the button in the initial position and wait for
the tanks to fill. Once completed, empty the
tanks completely using the cold and hot water
buttons. Once can also empty the tank through
the purge of the tank (nº 15). To do so, please
remove the screw.
12. SYSTEM INSTALLATION (FILTRATION)
1.
If the pressure is not at least 3 Kg/cm
need a pressure pump.
2.
Be sure to install the source in a potable water
inlet and at room temperature.
3.
Install a water inlet tap to be able to carry out
maintenance.
4.
Connect the inlet tap to the source through the
¼" tubing. The inlet connection is indicated on
the device.
5.
Next, connect the drainage to the indicated
outlet through the ¼" tubing.
6.
Disconnect the outlet from the active carbon
filters and the water inlet from the system. You
will need to take off the front lid for this. Plug the
machine into the electrical system and open the
water valve. Clean the active carbon filters with
tap water for 5 minutes until the water runs clear.
7.
Then, reconnect the carbon filter socket to the
tank inlet. Open the water valve and ensure that
there are no leaks and that osmotic water is
produced when pressing the cold water button.
8.
Place the button in the initial position and wait
until the tanks are filled. Once done, perform a
complete emptying of the tanks using the cold
and hot water buttons. The emptying can also
be performed through the tank purging (nº 15).
For this, remove the nut from the tank.
18
EN
, you will