Product Instructions
Introduction
These selectors are designed for up to 4 or 8 different sockets, and are easily connected to the I/O-port on
the Tensor DS D312 or PF3000 Controller. No adapter cable is needed, only the communication cable
4222 0470 .. and termination 4222 0443 00. Both selectors work with Tensor DS D312 & PF3000, not with
PF2000 or Tensor DS D302.
The basic functionality of the selector allows the operator to use the same tool for applications with differ-
ent socket sizes and /or various torque levels, and automatically switch parameter set accordingly.
NOTICE Only ferromagnetic sockets can be used
Technical specifications
Length
Width
Height
Weight
Power consumption
Operating voltage
Operating temperature
Humidity
Installation
When installing the Selector 4/8 please follow instructions below.
Connectors
Ref. No.
1
2
3
Hex Switch
There is a hex switch underneath the Selector.
Turn the switch to the right number/letter. The number indicates the node address on the I/O -Bus.
When delivered it is pre set to 5 for Selector 4 and 6 for Selector 8.
EN
Selector 4
210 mm
120 mm
65 (75) mm
1.1 kg
max 100 mA
(normal 70 mA)
24 VDC
0-50ºC (32-122ºF)
5-95% non-condensing
© Atlas Copco Industrial Technique AB - 9836 1733 02
Selector 8
410 mm
120 mm
65 (75) mm
2 kg
max 140 mA
(normal 70 mA)
24 VDC
0-50ºC (32-122ºF)
5-95% non-condensing
Description
+24 VDC input
I/O -Bus cable/Termination
Hex switch
Product Instructions
3