1. EQUIPMENT DESCRIPTION
Feed water for the ECO BASIC comes from the cold water pipe. Water enters into the first treatment phase
through the entry valve (3).
-Input valve (4): The electrically operated valve closes when the water level in the storage tank (9) reaches its
maximum and opens as the level falls.
-Sediment pre-filter (5):This filter consists of a cartridge that removes particles in suspension whose size is over
4 micron, and protects the activated charcoal filter (6).
-Activated charcoal filter (6):For hygienic reasons, feed water almost always contains a small chlorine
concentration (Cl). The chlorine disadvantages are the bad taste and smell. The activated charcoal completely
removes the taste and smell and protects the reverse osmosis membrane (7), which is sensitive to chlorine.
-Reverse osmosis membrane (7): A polyamide (TFC) membrane. This is where water is separated from the
majority of its salts, producing a concentrated flow and a permeated flow.
The concentrated pulls the saline content, which passes through the flow control valve (18) and the check valve
(19).Permeated water remains free from pollutants and is stored in the storage tank (9). from the water flow
through the rematerializing post filter and regulates the output water pHs
-Level probe (10): The entry valve (4) is controlled through the level and security control probe, opening or
closing it, and in its lower level disconnecting the pump (12).
- UVC lamp (11): Sequentially activated sterilizes the water in the storage tank.
-Storage tank (9): The already treated water is stored here. The osmotized water tank has a capacity 9 liters.
-Pump (12).The osmotized water from the storage tank (9) is pumped through the pump to the faucet (14).The
pump is switched on by opening the faucet.
-Unload bracket (17): Connects the concentrate outlet to the drain.
-Flushing solenoid valve (18):
The system is pre-adjusted, so that the temporized electromagnetic solenoid
valve performs a flushing of the reverse osmosis membrane every 5 hours, to increase its life time. At the same
time it controls the concentrate flow to drain.
-Electronic circuit(20): This module guarantees a correct operation of the system. It controls:
a) W ater quality inside the prefixed limits.
b) System blocking when the prefixed working hours have been exceeded. Please call an authorized technician
to replace the filters.
c) Control the pump operation in the minimum permeate water level.
-Faucet (14): Osmotized water outlet ready to be used.
-Transformer (22): Electrical connection at 12 V. Direct current.