TRANSMITTER OPTION SELECTOR
OPTION 1 - IN 1 SAFETY EDGE TYPE
ON
Resistive safety edge (8k2)
OFF
Contact safety edge (0 Ohms)
OPTION 2 - INHIBITOR SELECTION (*)
WITH RESISTIVE CONFIGURATION
(**)
ON
Resistive (8k2) safety edge
OFF
Contact safety edge (0 Ohms)
WITH OPTICAL CONFIGURATION (**)
ON
Transmitter inhibitor ENABLED
Receiver inhibitor ENABLED
OFF
Transmitter inhibitor ENABLED
Receiver inhibitor DISABLED
OPTION 3 - TRANSMITTER FREQUENCY
ON
Frequency 869,85 MHz, setting MUST match that of receiver
OFF
Frequency 868,95 MHz, setting MUST match that of receiver
* Transmitter and receiver must have same configuration otherwise will not work.
** Must be done with the programming button in the start-up (see programming
detail for optical safety edges)
RECEIVER OPTION SELECTOR
OPTION 1 - CLASS 2
ON
Class 2 enabled. Standard setting for safety operation.
OFF
Class 2 disabled
OPTION 2 - TRANSMITTER FREQUENCY
ON
Frequency 869,85 MHz
OFF
Frequency 868,95 MHz
OPTION 3 - RELAY TEST/INHIBITOR TYPE
ON
Normally Open contact
OFF
Normally Close contact
OPTION 4 - INHIBITOR INPUT CONFIGURATION
ON
Works with photocell test signal output
OFF
Works with auxiliary output.
OPTION 5 - INHIBITOR SELECTION
ON
Transmitter inhibitor ENABLED
Receiver inhibitor ENABLED
OFF
Transmitter inhibitor ENABLED
Receiver inhibitor DISABLED
CLASS 2:
It is very important that the selected frequency coincides with the transmitter. Otherwise the
system will not work. With class 2 Disabled the current consumption is less. This is a setting for
storing the product. Receiver test only checks the relay. Receiver will not work until all
programmed transmitters are identified.
Instruction Manual
PROGRAMMING PROCESS
(Table 1)
CODE MEMORIZATION
1.
Press PROG button for 1,5 sec.
2.- On hearing the acoustic signal stop pressing as the receiver will be logged into the memorizing code process.
3.- Prog. LED will be turned on indicating that you are programming transmitters.
4.- From this moment received transmitters will be memorized.
5.- In order to memorize push PROG button on the transmitter.
6.- The memorization of a code is acknowledge with one acoustic signal.
7.- The receiver will exit from memorization code process automatically after 10 seconds from the last transmitter input. This will be indicated
with two acoustic signals.
WARNING!!
Desired Transmitter and receiver options must be set before the transmitter code memorization, otherwise system will not
work correctly. If there is some doubt about configuration is recomended to do a memory reset.
Examples:
- If you want to use transmitter inhibitor TX OPTION 2 and RX OPTION 5 must be OFF before the transmitter code memorization.
-
If you want to use receiver inhibitor TX OPTION 2 and RX OPTION 5 must be ON before the transmitter code memorization.
MEMORY RESET
1.- Press PROG button for 3,5 seconds.
2.- After 1,5 seconds one acoustic signal will be heard indicating that you have entered the code memorization mode, maintain the button
pressed.
3.- After 3,5 seconds you will hear several acoustic signals for 10 secs.
(Table 2)
4.- Stop pressing the button.
5.- The WirelessBand will have reset all transmitters.
6.- The System remains in memorization process, ready to receive new transmitters
MEMORY FULL INDICATOR
In case of full memory you will hear several acoustic signals for 10 seconds upon trying to memorize a new transmitter.
The system can store 7 transmitters per channel.
LOW BATTERY INDICATOR
Low battery indication consists on 4 acoustic sounds each time a message is received from a programmed transmitter. Both, warning LED and
buzzer are set on simultaneously.
OSE POWER SUPPLY TIME PROGRAMING PROCESS (only with OPTION 4 - ON)
1.
Press PROG button for 1,5 sec.
2.- On hearing the acoustic signal stop pressing as the receiver will be logged into the memorizing code process.
3.- Prog. LED will be turned on indicating that you are programming transmitters.
4.
Press PROG button again for 1,5 sec.
5.- Prog. LED will flash indicating that you are programming power supply time.
6.- waiting time. You must wait for time you need for having the power supply for the OSE.
7.- Press PROG button again for 1,5 sec. receiver will exit the process and power supply time will be memorized. If this time is less than 10sec.