6920-ISIS-US/F/E#4 pages.qxd
US
2. AVENT ISIS Breast Pump parts
PUMP
a)
Funnel cover
b)
Let-down massage cushion
c)
Pump cover
d)
Silicone diaphragm
and stem*
e)
Handle
f)
Pump body and funnel
g)
White star valve*
3. To clean and sterilize your pump
Before you use your breast pump for the first
time and every time before use:
Separate all parts, then wash in the top shelf of the
dishwasher or in warm soapy water and rinse. Do not
use antibacterial cleaners/detergents.
Sterilize in an AVENT Steam
Sterilizer (electric or microwave), or by boiling for 10
minutes. If using an AVENT Steam Sterilizer, the
pump will remain sterile in the Sterilizer for 3 hours
provided the lid is not removed. Open lid to dry for
storage/assembly. (Always use distilled water.)
4. To keep your pump sterile and
compact for travel
After sterilizing all parts, you can secure the cover (a) over
the funnel and let-down massage cushion and screw the
travel cover (m) onto the pump body (f) in place of the
bottle or bottle holder.
2
1/3/04
5:17 pm
Page 2
BOTTLE
h)
Reusable bottle (125 ml/4 oz)
or Disposable System
i)
Stand
j)
Dome cap
k)
Newborn nipple (0m+)
l)
Screw ring
m)
Travel cover
n)
Sealing disc
*spares included
5. Using the AVENT Disposable System
with your ISIS Breast Pump
Simply replace the AVENT Reusable Bottle with
the AVENT Disposable Nurser fitted with a
disposable liner.
6. How to assemble your AVENT
ISIS Breast Pump
Please refer to diagram 6 at the beginning of this leaflet. Separate all parts
and ensure pump has been cleaned and sterilized as in section 3:
1)
Wash your hands thoroughly. Click the white star valve (g) into the
pump body (f) from underneath making sure the flat side of the valve
is downwards and the star side is facing up.
2)
Place the pump body (f) onto the bottle (h).
3)
Twist gently clockwise until it catches. DO NOT OVERTIGHTEN!
4)
Place the silicone diaphragm with stem (d) into the pump body (f).
Make sure it fits securely around the rim by pressing down with your
fingers to ensure a perfect seal. (This is easier if assembled while wet.)
5)
Place the forked end of the handle (e) under the diaphragm stem (d) and
push down gently on the handle until it clicks into place.
6)
Carefully insert the let-down massage cushion (b) into the pump funnel (f)
making sure it is perfectly sealed all round the rim of the funnel. (This is
easier if assembled while wet.)
7)
Click the pump cover (c) onto the pump body (f). To make the pump
completely stable insert the bottle into the stand (i).
US
3