Trouble
Machine does not start
Trigger clamps
Machine rotates too
slowly
Motor sticks / jams
Gearbox makes loud
noises
Tool not able to be
clamped
Reversing
"drilling / hammering"
clamps
IMPORTANT!
The maker will not take responsibility for damage or malfunction as a result of the Testing Pump being incorrectly
used or, applied for a purpose for which it was not intended.
The maker guarantees to the machine owner 12 months against any manifacture defect.
This guaranteee do not cover the parts wich are consumables.
Note: to apply the guarantee its necesary to send the "GUARANTEE CERTIFICATE" duly filled within one week after
purchased the machine to the maker.
14
TROUBLE / PROBABLE CAUSE / SOLUTION
Probable cause
- Air not connected
- Rotor rusted by huminity
- Vanes jam (worn)
- Gearbox blocks
Contaminates in valve
- Operating pressure too low
- Rotor grinds on end plates /
cylinder bushing
- Gear parts jam
- Vanes worn or broken,
broken parts stick between
rotor and cylinder bushing
- No lubrication - ball bearings
have run dry, rotor has
rubbed on end plates
- Coarse impurities in motor
area jammes between rotor
and cylinder bushing
- Needle cages defective
- Toothing is clattering
- Ball bearing defectiv
- Drill chuk defective
- diameter of tool too small
- Dirt in reversing area
- Steel rollers clamps
- Connecting and open air line
- Disasseble and clean motor, check and test
- Disassemble motor, clean it and replace worn parts
- Disassemble and clean gearbox and replace
- Increase operating pressure (on the machine)
- Disassemble and clean motor, replace worn parts
- Disassemble and clean gear, replace worn or
- Disassemble and clean motor, replace worn parts
- Disassemble and clean motor, replace worn parts
- Disassemble and clean motor, replace worn parts
- Disassemble and clean gearbox, replace worn
- Disassemble gear and replace defective parts
NOTES
GUARANTEE
Solution
service unit for function
worn parts
- clean sit
to 6 bar
damaged parts
parts
- Change drill chuck
- use bigger tool
- Clean machine