Technical Specifications - Perel FT120C Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
10.

Technical Specifications

power supply ............................................................................ 220-240 V~, 50 Hz, 230 W
fuel .......................................................................................................... diesel/kerosene
IP rating ................................................................................................................... IPX4
FT120C
power.................................................................................................................... 20 kW
heat output ................................................................................................... 68240 BTU/h
fuel tank capacity ...................................................................................................... 19 L
heating surface ..................................................................................................... 400 m²
fuel consumption ................................................................................................ 1.986 L/h
air flow .............................................................................................................. 550 m³/h
dimensions ........................................................................................ 750 x 315 x 415 mm
weight .................................................................................................................... 14 kg
Information requirements for gaseous/liquid fuel local space heaters
Model identifier(s): FT120C
Indirect heating functionality: no
Direct heat output: 20 (kW)
Indirect heat output: N.A. (kW)
Fuel
Select fuel type
Item
Heat output
Nominal heat
output
Minimum heat
output
(indicative)
Auxiliary electricity consumption
At nominal heat
output
At minimum
heat output
In standby
mode
V. 05 – 23/04/2020
FT120C/FT130C
liquid
Symbol
Value
Unit
P
20.0
kW
nom
P
N.A.
kW
min
el
0.002
kW
max
el
N.A.
kW
min
el
N.A.
kW
SB
kerosene
Item
Symbol
Useful efficiency (NCV)
Useful efficiency at
η
nominal heat output
Useful efficiency at
minimum heat output
(indicative)
Type of heat output/room temperature control
(select one)
single stage heat output, no room
temperature control
two or more manual stages, no room
temperature control
with mechanic thermostat room temperature
control
with electronic room temperature control
with electronic room temperature control plus
day timer
with electronic room temperature control plus
week timer
9
Space heating emissions (*)
NO
x
79 [mg/kWh
] (GCV)
input
Value
Unit
100
%
th,nom
η
N.A.
%
th,min
no
no
no
yes
no
no
©Velleman nv

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ft130c

Tabla de contenido