Symptom
Probable Cause
Poor bass response
Crossover set incorrectly
Impedance load at amplifier is
too low .
Battery fuse blowing
Short in power wire or incor-
rect wiring .
Fuse used is smaller than rec-
ommended .
Actual current exceeds fuse
rating .
Amplifier fuse blowing
Fuse used is smaller than rec-
ommended .
Impedance load at amplifier is
too low .
Speaker is blown with shorted
outputs
Actual current exceeds fuse
rating
2
Action To Take
Reset crossovers . Refer to the Internal Cross-
over Configuration section of this manual for
detailed instructions .
Check speaker impedance load if below 2Ω,
rewire speakers to achieve higher impedance
.
Check power wires and ground connections
and repair or replace as needed .
Replace with proper fuse size .
Check speaker impedance load if below 2Ω,
rewire speakers to achieve higher impedance
.
Replace with proper fuse size .
Check speaker impedance load if below 2Ω,
rewire speakers to achieve higher impedance
.
Check system with known working speakers
and fix or replace as needed .
Check speaker impedance load if below 2Ω,
rewire speakers to achieve higher impedance
.