Installation
Prepare the Pool
1. Manually vacuum the pool if excessive debris is present,
and make sure the pool filter and pump basket are clean.
2. Close the pool main drain line.
3. Adjust the return lines to blow downward to
break up surface circulation and
ensure complete cleaning coverage.
• Loosen the fitting lock ring
• Redirect the eyeball downward
• Retighten the lock ring
If the return fitting cannot be adjusted, the fitting
MUST be replaced with Zodiac return line
diverter (part #W90153 for 1-1/2", #W90155
for 2" or #W24100 for pools without return fittings) .
Assemble the Cleaner
Stretch the finned disc over the foot pad with the fins
pointing up. The disc should fit securely in the groove
and rotate freely on the pad.
For US/Mexico installations only. Slide the wheel
deflector over the extension pipe, clips up, until it snaps
onto place. The deflector should rotate freely.
Assemble the Hose
For corner or end installations, connect enough
hose to reach the farthest point of the pool and
then add one more section.
Skimmer or
Dedicated Suction
Cleaner Line
Position the hose weight(s): one for US/Mexico installations, in the middle of the first hose section or
about 20" back from end of hose; and two for Canadian, in the middle of the second hose section or
about 60" (1.5 m) back from the end of the hose.
4
4
Estire
For center installations, connect enough hose to
reach the farthest point of the pool and then add
two more sections.
1 Hose
Section
Skimmer or
Dedicated Suction
Cleaner Line
2 Hose
Sections