Operation; Switch On/Off; Display - Festool TURBO II M - 8 WP Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
Turbo II M
GB
High leakage current > 10 mA. Install an addi-
tional protection conductor with a minimum
cross section of 10 mm
7

Operation

7.1

Switch on/off

Switching on
Turn main switch [1-1] to "I".
Turbine goes to Sleep mode - Speed 0
Press ON button [1-8].
Turbine goes to Standby mode - Speed minimal
The turbine controls itself depending on the ex-
traction requirement.
After 10 min. without any extraction requirement the
system purges the pipe system and goes into Sleep
mode.
7.2

Display

Service:
6543 h
Status:
Betrieb
Zustand:
Warnung
W1
Temp. hoch
E
D
Operating status on display
Operating
Significance
status B
Operation
Extraction unit is in operation, extraction requirement available
Standby
Extraction unit runs at low speed, no extraction requirement available.
Sleep
Extraction unit is stationary, control is active. Automatically happens after set Standby time
Dedusting
Extraction unit dedusts.
Shutdown
Extraction unit shuts down and goes to Sleep mode
Warnings on display
System continues to run. Warning LED [1-6] illuminates yellow.
Failure code
Warning D
E
W1.1
Temp. high
22
2
Cu.
A
B
C
Warning
Significance
light
Flashes 3
High motor temperature
times - Pause
Extraction unit runs at
reduced power
If the device receives a switch-on signal (= extraction
requirement) from the EAA, it starts automatically.
If there is no EAA signal, a switch-on button can be
connected to the control system instead with which
the system can be manually switched on and off. Au-
tomatic Sleep mode is not possible here. In the event
of extended work interruptions, the system must be
manually switched to Sleep mode.
Switching off
Press the OFF button[1-9].
Turbine goes into Sleep mode after purging and
dedusting.
Pressing the button again during purging mode
immediately switches the system to Sleep mode.
Turn main switch [1-1] to "0".
Turbine switches itself off.
A
Remaining operating hours until next service
B
Operating status
C
Operating status (OK, Warning, Failure)
D
Brief information on Failure/Warning
E
Failure code (W/F)
Solution
Provide better cooling.