120611 Primera-Line Blitzschutzadapter_120611 Primera-Line
Operating instructions
SPD 3) are damaged by voltage peaks in a
230V network. Voltage peaks can arise from
indirect lightning or inductive loads activation,
such as engines, ovens or lamps.
For a correct operation the device should be
connected to a socket with a professionally
installed protective conductor.
When the green signal lamp 2 on the overvol-
tage protection adaptor is lit, the overvoltage
protection is active.
When the green signal lamp 2 on the overvol-
tage protection adaptor is no longer lit,
protection is no longer ensured and the over-
voltage protection adaptor must be replaced.

Technical data

Name: SP 230 V
Supply voltage: 230 V~ / 50 Hz
Max. current-carrying capacity: 16 A
SPD according to EN 61643-11/A11:2007: Type 3
Highest continuous voltage U
Combined surge U
Combined surge U
Protection level U
Protection level U
Operation
Connection
CAUTION
Damages due to unsuitable power supply
Risk of damages to the overvoltage
protection adaptor by too high mains
voltage.
• Check the overvoltage protection adaptor for
allowed mains voltage on identification plate.
• Connect the overvoltage protection adap-
Primera-Line
: 250 V~ / 50 Hz
C
(L-N): 6 kV
OC
(L/N-PE): 6 kV
OC
(L-N): 1.8 kV
p
(L-/N-PE): 1.8 kV
p
9