MENU → SETTINGS
→ Offset
→ Room temperat-
ure: K
→ Outdoor temper-
ature: K
→ Factory settings
2.11.4
-- Installation configuration menu item
MENU → SETTINGS → Installer level → Installation configuration
→ Installation
→ Water pressure: bar
→ eBUS components
→ Adaptive heat curve:
→ Control:
→ Heat generator 1
→ Status:
→ Current flow temperature: °C
→ Circuit 1
→ Status:
→ Target flow temperature: °C
→ OT switch-off threshold: °C Enter the upper limit for the outdoor temperature. If the
→ Heat curve:
→ Min. target flow temperat-
ure:°C
0020298974_00 sensoHOME Operating and installation instructions
Comparison of the temperature difference between the measured
value in the control and the value for a reference thermometer in the
living room.
Comparison of the temperature difference between the measured
value in the outdoor temperature sensor and the value for a reference
thermometer in the living room.
The control resets all of the settings to the factory settings and calls up
the installation assistant.
Only the competent person can call up the installation assistant.
List of eBUS components and their software versions
Automatic fine adjustment of the heat curve. Prerequisite:
– The suitable heat curve for the building is set in the Heat
curve: function.
– The correct zone is assigned to the control or the remote
control in the Zone assignment: function.
– Expanded is selected in the Room temp. mod.: func-
tion.
R.temp.contr
Weath.-
comp.
outdoor temperature rises above the set value, the control
deactivates heating mode.
The heat curve (→ section "Product description") is the de-
pendence of the flow temperature on the outdoor temperat-
ure for the desired temperature (target room temperature).
Enter the lower limit for the target flow temperature. The
control compares the set value with the calculated target
flow temperature, and regulates to the larger of these val-
ues.
Product description 2
It is controlled via the room temperature.
It is controlled via the outdoor temperature
as soon as an outdoor temperature sensor is
connected.
11