Descargar Imprimir esta página

Wavetek Meterman SF10 Manual De Instrucciones página 5

Publicidad

• Brush
• Bürste
• Pincel
• Brosse
• Pointed tip probe
• Meßspitze
• Punta de pruebe
• Pointe de mesure
To use the Short Finder Brush, place the on/off switch in the "ON" posi-
tion. You will hear a beep indicating the unit is ready. You will obtain the
best results using the Short Finder Brush by following these simple steps:
❶ Remove all sources of power from the circuit being tested.
Caution: Always make sure there is NO POWER applied to the circuit you
are testing. Although the Short Finder Brush is internally protected against
accidental external voltage to 50V, contacting a live circuit with the con-
ductive brush tip may cause damage or present a safety hazard.
❷ Place the reference probe in contact with the circuitry location from
which you want to measure.
❸ Sweep the brush probe over the remaining circuitry. A short is indicat-
ed by an audible tone.
Operating Instructions
– 3 –
• On/off switch
• Ein/Aus
Schalter
• Tecla de
encendido
• Interrupteur
OFF
ON
• Reference
probe
• Referenz-
meßspitze
• Punta de
refencia
• Pointe de
référence

Publicidad