Both standard and "eternal" potentiometers share the same type of connection. To install the "eternal" crossfader,
please follow these steps.
5.2.8. Replaceable VCA Faders and Crossfaders / "eternal" upgrade
Once any of these components has reached the end of its operating life, it can be easily replaced following these
simple steps:
1. Remove the buttons and the screws on the bottom panel.
2. Remove the two screws that hold the potentiometer to be replaced, and take it out of the mixer.
3. Disconnect the multipin connector.
4. Replace the part with an identical one or with the "eternal" crossfader.
5. Connect the multipin connector.
6. Place the fader back in the mixer and secure it with the two screws.
7. Secure the bottom cover plate with its screws and insert the buttons back in.
Always use original ECLER replacement parts.
5.2.9. MASTER Levels
The NUO4 features two main output level controls MASTER 1 (24) and MASTER 2 (25). The OUT 1 (55-56) level
is controlled by the MASTER 1 level knob. The OUT 2 (54) level is controlled by the MASTER 2 level knob.
The BAL balance potentiometer (27) affects MASTER 1 output as well as MASTER 2 output.