Installation And Connection - Ecler MPAGE4 Manual De Instrucciones

Ocultar thumbs Ver también para MPAGE4:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3. INSTALLATION and CONNECTION

Installing a MPAGE4 unit consists of the following steps:
1.
Installation of wiring using a standard CAT5 cable between the BASE connector of
the MPAGE4 (7) and the PAGER connector on the rear panel of the MIMO54.
Pin 1 to Pin 1
White/orange
Pin 2 to Pin 2
Orange
Pin 3 to Pin 3
White/green
Pin 4 to Pin 4
Blue
Pin 5 to Pin 5
White/blue
Pin 6 to Pin 6
Green
Pin 7 to Pin 7
White/brown
Pin 8 to Pin 8
Brown
The cable transmits the zone selection control signals as well as the audio signal of
the goose-neck microphone and the signal for the carillon melody, if activated. The
phantom power required by the MPAGE4 unit is also supplied by the MIMO54 using
the same cable.
Wiring of RJ-45 connector
MIC+
MIC-
GND
VCC (+10V)
ZONE 1
ZONE 2
ZONE 3
ZONE 4
MPAGE4
CHIME
MIMO54
OUTPUT
ZONE 1
ZONE 3
ZONE 2
PAGER
PAGER
PRIO
EVAC
0
VOL
INPUT 5
MIC
LINE R
LINE L
10
5

Publicidad

Tabla de contenido
loading

Tabla de contenido