2.
Excessively high grass
a.
Mow once at a high cutting height, then mow again at desired
height or make a narrower cutting swath
3.
Dull blade
a.
Sharpen or replace blade
Tractor stopped or will not start
1.
Electrical system fault
a.
Shut off and restart tractor
b.
If problem persists, contact an authorized service dealer
The blades do not rotate /blades stopped
1.
Overload
a.
Allow deck motor(s) to cool/raise deck height
2.
Low battery
a.
Return home, plug into charger
The blade(s) stopped when traveling in reverse
1.
Blade(s) stopped
a.
Restart blade(s) (PTO)
b.
Make sure Reverse Caution Mode is activated
Reduced Speed
1.
Low battery
a.
Charge battery as instructed in the battery charger manual
2.
Overload
a.
Raise deck
LCD Screen Messages
Brake Switch Fault: The deck and drive shut off. Power off and restart tractor. If
problem persists contact qualified service personnel.
Accelerator Pedal Sensor Fault: The deck and drive shut off. Power off and
restart tractor. If problem persists contact qualified service personnel.
Seat Switch Fault: The deck and drive shut off. Power off tractor, sit in seat and
restart tractor. If problem persists contact qualified service personnel.
Cutting Deck Overload: The deck and drive shut off. Power off the tractor, clean
under the deck as instructed in the Post-Operation Tractor Care section and restart
the tractor. Raise the deck and/or cut at a slower pace. If problem persists contact
qualified service personnel.
Drive Motor Over Current Fault: The deck and drive shut off. Power off, let
the tractor cool and restart tractor. If problem persists contact qualified service
personnel.
SERVICE AND MAINTENANCE
Drive Motor Control Fault: The deck and drive shut off. Power off and restart
tractor. If problem persists contact qualified service personnel.
Self Test Fault: The deck and drive shut off. Power off and restart tractor. If
problem persists contact qualified service personnel.
Electrical Faults: The deck and drive shut off. Power off and restart tractor. If
problem persists contact qualified service personnel.
Battery Temperature Low: Move the tractor to a warm location and allow the
battery to warm. If problem persists contact qualified service personnel.
High Temperature Faults: Power off, let the tractor cool and restart tractor. If
problem persists contact qualified service personnel.
Charge Port Door is Open: The tractor will come to a stop and shut off. Close the
charge port door and restart tractor. If problem persists contact qualified service
personnel.
Low Battery Warning: The battery is low and should be charged as soon as
possible.
Sharpen Blade Warning: When this warning is displayed, the blades should be
checked and sharpened.
Check Tire Pressure Warning: When this warning is displayed check and adjust
the tire pressure.
23