Descargar Imprimir esta página

Sensopart FT 55-RLHM Serie Instrucciones De Servicio página 3

Interruptor de proximidad láser

Publicidad

Press
FT 55-RLHM
1000
Press
Q1
Q2
Unlock 3 s
2 - service view 1
1000
menu
teach
Teach Q1 / Q2
1 - main view
Press teach
Q1
Q2
back
ok
Teach Q1 - SP
SinglePoint
Teach on
object
canc
ok
Q1 - WIN - SP1
Window
Teach on close
switchpoint
canc
ok
Q1 - 2Po - SP1
TwoPoint
Teach on close
switchpoint
canc
ok
Detect Mode
DetectAll
Distance
Dist+Intens
canc
set
Enter LayerDtct
LayerDtct
LayerDtct
affects
Q1 + Q2
canc
ok
OK
Offset LDM
Teach display
offset?
canc
yes no
GoodTrgt
GoodTrgt
Set Q1 as
Good target
only Q1
canc
set
Antivalent
Antivalent
Set Q2 as
Antivalent
only Q2
canc
set
Menu
Config Q1
Switchpoint
OK
Hyst size
N.O. / N.C.
SmartFunc
PNP / NPN
DetectMode
Config Q2
OK
Switchpoint
Hyst size
N.O. / N.C.
SmartFunc
PNP / NPN
DetectMode
Config In
*Teach In* I Disabled I Laser I Key lock
OK
Settings
Factory set
OK
Speed
Display
Password
Info
*xxx* Factory setting
www.sensopart.com
Q1
SP
Dist
Press
Q2
SP
Dist
IN
Teach In
3 - service view 2
SET
Teach Q1
SinglePoint
OK
Window
TwoPoint
canc
set
SET
Teach Q1 - SP
Set Q1 - SP
Confirm obj. or
xxx mm
OK
OK
teach backgr.
Live: xxx mm
canc
ok
set
Q1 - WIN - SP1
Q1 - WIN - SP2
xxx mm
Teach on far
OK
SET
OK
Live: xxx mm
switchpoint
canc
ok
set
Q1 - 2Po - SP1
Q1 - 2Po - SP2
xxx mm
Teach on far
OK
SET
OK
Live: xxx mm
switchpoint
set
canc
ok
Teach Q1 - DAM
Set Q1 - DAM
Teach on
xxx mm
SET
STOP
background
Live: xxx mm
canc
start
set
Offset LDM
Teach LDM
YES
SET
OK
xxx mm
Close distance
Live: xxx mm
Q1
set
canc
ok
NO
SET
xxx mm
OK
SP1 (1000)
OK
Live: xxx mm
SET
1)
OK
1)
Change of the hysteresis in Layer Detection mode layer requires new teach-in
SET
*N.O.*
OK
N.C.
SET
On delay
OK
OK
0 ms I 20 ms I 50 ms I 100 ms I Custom
Off delay
Impulse
OK
Counter
SET
OK
*Autodetect* I PNP I NPN I PushPull
SET
*Distance*
2)
OK
Dist+Intens
2)
Only Detect-All Mode
SET
xxx mm
OK
SP1 (1000)
OK
Live: xxx mm
SET
1)
OK
Change of the hysteresis in Layer Detection mode layer requires new teach-in
1)
SET
*N.O.*
OK
N.C.
SET
On delay
OK
OK
0 ms I 20 ms I 50 ms I 100 ms I Custom
Off delay
Impulse
OK
Counter
SET
OK
*Autodetect* I PNP I NPN I PushPull
SET
*Distance*
2)
OK
Dist+Intens
Only Detect-All Mode
2)
SET
SET
Yes
OK
*No*
SET
OK
*1000 Hz* I 200 Hz I 100 Hz I 40 Hz I 20 Hz I 10 Hz
SET
OK
Turn display
OK
On I *Off*
Screensave
LED Scheme
3)
Q output I Layer
SET
Password
OK
On I *Off*
OK
0
0
1
1
2
2
set
BACK
OK
(Device name) I (Part number) I (Software version)
Änderungen vorbehalten | subject to change | sous réserve de modifications | salvo modificación
Q1 - WIN - SP2
xxx mm
Live: xxx mm
set
Q1 - 2Po - SP2
xxx mm
Live: xxx mm
set
Set close LDM
Teach LDM
Set far LDM
xxx mm
SET
OK
Far distance
xxx mm
Live: xxx mm
Q2
Live: xxx mm
set
canc ok
set
Only Layer-Detection Mode
3)
Operation modes
TP = Teach point
SP = Switchpoint
Hyst. = Hysteresis
Single-Point Mode
Object/Object teach:
TP1=TP2=SP1
N.O.
120/200
mm
Object/Background teach:
TP1
N.O.
120/200
mm
Hysteresis adjustable Small I Medium I Standard I Wide
Window Mode
TP1=SP1
N.O.
Hyst.
120/200
mm
Hysteresis adjustable Small I Medium I Standard I Wide
Two-Point Mode
TP1=SP1
N.O.
120/200
mm
Hysteresis settings do not influence the switching point settings; the switching points define
the hysteresis size.
Detect-All Mode
N.C.
Hyst.
No blind
zone
120/200
mm
Layer-Detection Mode
TP nah
N.C.
120/200
mm
Yes → Display = 0 mm / + ... mm / - ... mm
Teach display offset
No → Display = real distance
Good Target
If activated, Q1 is ON whenever an object is within the working range and the signal quality is
sufficient.
Antivalent
If activated, N.C. and N.O. function are available at the same time.
Example Q1 N.O.:
Example Q2 N.C.:
Config Q1 / Config Q2
Smart functions (SmartFunc)
On delay
H
Input
L
H
Delay
Output
L
Off delay
H
Input
L
H
Output
Delay
L
Impulse
H
Input
L
H
Output
Impulse
L
Counter
H
Input
1
2
3
L
H
Output
L
Config In
In functions
Laser off
+UB = Laser on
Key lock
+UB = Keys are lock
Teach in
Q1: 3 s + 1 s TP1 / TP2
Q2: 6 s + 1 s TP1 / TP2
N.O./N.C./antivalent: 10 s + 1 s; accepted if no action for 10 s
NPN/PNP/Auto: 13 s + 1 s; accepted if no action for 10 s
4)
Switching affects both outputs
Settings
Deletes all modifications that are done since set up of the sensor, all
Factory set
settings are reset to original factory settings.
Turn display
Display is turned 180°.
Display
Screensave
ON = Display turns off after 1 minute and gets locked.
OFF = Display stays onn.
LED flashing behaviour corresponds to the switching
Q output
behaviour of the switching outputs (s. illustration G).
LED scheme
LED flashing behaviour corresponds to the number of
Layer
layers (s. illustration G). LED updating time is not true to
cycle.
Definition of unlock password. This has to be entered each time when
Password
unlocking the sensors. If password is forgotten, a master password can be
obtained at the SensoPart support.
E
Object =
I Background =
Hyst.
600/1000
mm
50%
SP
50 %
TP2
Hyst.
600/1000
mm
TP2=SP2
Hyst.
600/1000
mm
TP2=SP2
Hyst.
600/1000
mm
TP1
SP1
SP2
Hyst.
600/1000
mm
Teach offset
(set value)
SP1
SP2
TP fern
Hyst.
Hyst.
Hyst.
"+ ... mm"
"- ... mm"
600/1000
"0 mm"
mm
adjustable
in
1 ms steps
adjustable
in
1 ms steps
adjustable
in
1 ms steps
4
1
2
3
4
1
2
-UB = Laser off
-UB = Keys are unlocked
(s. illustration E)
4)
(s. illustration F)
4)
068-14886 03.06.2020-01
3

Publicidad

loading

Este manual también es adecuado para:

Ft 55-rlhm-600Ft 55-rlhm-1000