LTC 8900 | Manual de instrucciones | Instalaciones de configuración satélite
LTC 8902 for Monitors 1 to 64
8 LTC 8934 Video Output Modules
are Required for Monitors 1 to 64. Set all Termination
Switches to ON for all Modules.
LTC 8902 for
Monitors 65 to 96
8 LTC 8934 Video Output Modules
are Required for Monitors 65 to 128.
Set all Termination Switches to ON
for all Modules.
Monitors 33–64
First Level LTC 8902
Monitors 1 to 64
Each Line Represents an
LTC 8809 Ribbon Cable
Monitors
65–96
Second Level LTC 8902
Monitors 65 to 128
FIGURA 55: Módulo, terminación y cableado de interconexión para sistema de 512 cámaras y 128 monitores
Bosch Security Systems | Novemeber 7, 2008
Video Interconnect LTC 8809 Cables
16 LTC 8921 Video Input
Modules are Required for
Camera Inputs 1 to 256
Video Interconnect LTC 8809 Cables
Set the LTC 8921 Module Termination Switches
in the ODD Numbered Slots to OFF (in both Second Level LTC 8902 Bays).
Front View – Module Placement and Termination Settings
Monitors 1–32
Upper
LTC 8809
Lower
Ribbon
LTC 8809
Cable
Ribbon
Cable
To "A1"
"B1"
"D"
"C"
"B "
"A"
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
"C1"
To "D1"
"A2"
"B2"
"C2"
"D2"
For 256 Cameras,
Monitors
16 LTC 8809
97–128
Ribbon Cables
are Required to Jump
Upper
from First Level
LTC 8809
Lower
Ribbon
"Loop" Outputs to
LTC 8809
Cable
Second Level
Ribbon
Cable
"Video In" Inputs
To "A1"
"B1"
"D"
"C"
"B "
"A"
"C1"
4
3
2
1
4
3
2
1
4
3
2
1
4
3
2
1
To "D1"
"A2"
"B2"
"C2"
"D2"
Each Line Represents an
LTC 8809 Ribbon Cable
Rear View – LTC 8809 Interconnect Cable Routing
System Cameras Connect
to the First Level LTC 8903
Video Input Bay
16 LTC 8921 Video Input
Modules are Required for
Cameras 1 to 256
First Level LTC 8903
First Level LTC 8903
Cameras 257–512
Cameras 1–256
Video Looping
Connections
Second Level LTC 8903
Second Level LTC 8903
Cameras 1–256
Cameras 257–512
Set the LTC 8921 Module Termination Switches
in the EVEN Numbered Slots to ON (in both Second Level LTC 8903 Bays).
8 LTC 8808 Panels are Required
for Camera Inputs 1 to 256
To Video
In "B"
8 LTC 8808 Panels are Required
To Video
for Camera Inputs 257 to 512
In "A"
Lower
LTC 8809
Ribbon
LTC 8903
Cable
To Video
In "B"
LTC 8903
LTC 8809
Ribbon Cables
LTC 8809 Cable for
LTC 8903
Cameras 241 to 256
LTC 8903
System Cameras Connect
to the First Level LTC 8903
Video Input Bay
16 LTC 8921 Video Input
Modules are Required for
Cameras 257 to 512
Set all LTC 8921 Module
Termination Switches Inside the
First Level LTC 8903 Bays to OFF
Video
Looping
Connections
16 LTC 8921 Video Input
Modules are Required for
Camera Inputs 1 to 256
Upper
LTC 8809
Ribbon
Cable
To Video
For 256 cameras,
In "A"
16 LTC 8809 Ribbon
Cables are Required to Jump
from First Level "Loop"
Outputs to Second Level
"Video In" inputs
LTC 8809 Cable for
Cameras 1 to 16
ES | 70