First Start-Up; Maintenance And Conversion Of The Appliance; Handover; Environment And Recycling - stori ETS 200 Instrucciones De Uso Y Montaje

Acumuladores dinámicos
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Actuation without heating contactor:
If it is not intended to install a heating
contactor (in part a requirement by the
electricity utility company), the thermal
relay installed at the factory can be used.
To do this, either the electricity utility
company „LF+N" signals or the „SH+N"
signals are to be connected directly to the
„L-SH+N" terminals of the heat storage
appliance. The references marked * in the
circuit diagram opposite are to be taken
into consideration in this respect.
The heating elements in the appliance will
not be switched on until LF clearance is
issued by the electricity utility company, and
the electronic charging regulator issues
clearance for charging.
For operation with „single-wire
control", a bridge is to be laid
between „N" and „A2/Z2".
Take proper note of the appliance
rating plate:
After the electrical connection has been
carried out, the connected load and the
rated charging duration of the appliance are
to be marked in the appropriate boxes on
the rating plate and in the circuit diagram in
these Installation Instructions by ball-point pen.
2.5.3 Appliance ready for operation
Cleaning the appliance K - L
The opened appliance is to be cleaned out
after the storage bricks have been set in
position and used. To do this, the blower and
the
air flow device
are to be removed.
Unscrew the air flow device (16) and
draw it out.
⇒ Raise the blower fan (M1) slightly after
releasing the screws (do not unscrew)
located at the front of the retaining angle
element, and draw it out (pay attention to
the way in which the cables are laid).
With some appliances, to do this the
discharge temperature regulator (N5) is to
be unscrewed, including the retaining plate.
When setting the dismantled parts aside,
care must be taken to ensure that the
connection wires are not damaged.
⇒ Clean the baseplate and blower fan (take
care not to damage the blades). Then
reinstall the blower, the temperature
limiter if applicable, and the
(make sure the cables are correctly laid).
Close the appliance M - Q
⇒ Suspend the inner front wall with the
thermal insulation, tilted slightly and
obliquely forwards, on the upper edge and
screw it to the lower edge;
Suspend the right-hand side wall in
position at the top and bottom;
Suspend the front wall in position at the
front, pivot it at the bottom towards the
appliance, and secure it with 3 screws (in
this situation, make use of the holes with
inside threads in each case);
Screw the air outlet grille into place, hand
tighten the screw securely, and then undo
the screw one full turn anti-clockwise;
22
Place the air intake grille obliquely at the
bottom onto the burls on the base of the
appliance, pivot it around at the top, and
engage it behind the air outlet grille.

2.6 First start-up

Danger, short circuiting at the
load control
Be careful that teh test equipment probes
do not slip off of the contacts as this will
cause a shirt circuit and damage the load
control.
If this occurs, the control light will glow
green continuously!
2.6.1 Function test
The function of the blower fan for the
storage part is to be checked by switching on
the room temperature regulator.
2.6.2 Charging
Once the function test has been carried out,
the appliances can be taken into operation
without any particular additional precautions.
Charging is carried out either manually by
means of the adjuster of the electronic charging
regulator, or automatically by means of the
existing
elthermaticc
During the first charging, the charge is to be
determined in kWh, and compared with the
maximum permissible charge from the cold
state as indicated in the Technical Data. The
charge which is determined must not exceed
the highest permissible charge from the cold
state.
At the first charging, a smell may be
apparent, and care should accordingly
be taken to ensure that the room is
suitable ventilated (1.5 times air change, e.g.
window in tilted position). First charging in
a bedroom should as far as possible not be
carried out while anyone is sleeping in it.
2.7 Maintenance and
conversion of the appliance
In the event of re-installation of an appliance
which has been dismantled for the purpose
of repair, or which has already been in
air flow device
ETS 700
Nr.
charging control device.
®
074489 -
7673 -
000009
3/N/PE ~ 400 V 50 Hz
5,25 5,83 6,42 7,0 6,75 7,5 8,24 9,0
X
5
6
7
8
9
10
1/N/PE ~ 230 V 50 Hz
1,7
26 W
Made in Germany
operation elsewhere, the same procedure is
to be followed as for first-time installation in
accordance with these Installation Instructions.
In this case, particular attention must be paid
to ensuring:
- That any parts of the thermal insulation on
which damage or changes can be identified
which could impair safety must be replaced
by new parts. Before the appliance is taken
into operation, the insulation test and
measurement of the rated consumption
must be carried out.
2.7.1 Conversion of the appliance
The instructions provided with the individual
fitting sets are determinant with regard to
conversion, extension, and installation work.

2.8 Handover

Explain the functions of the appliance to the
new user. Draw their attention in particular
to the safety instructions. Hand over the
Instructions for Use and Installation to the
new user.
3. Environment and
recycling
Please help us to protect the environment by
disposing of the packaging in accordance with
the national regulations for waste processing.
4. Garantie
For guarantee please refer to the respective
terms and conditions of supply for your
country.
The installation, electrical connection
and first operation of this appliance
should be carried out by a qualified
installer.
The company does not accept liability for
failure of any goods supplied which are not
installed in accordance with the
manufacturer's instructions.
Symbol of rating plate
(Example ETS 700)
373 kg
kW
h
kW
Gross weight
Charge loading
Discharge loading
Addional heating element
Fan

Publicidad

Tabla de contenido
loading

Productos relacionados para stori ETS 200

Este manual también es adecuado para:

Ets 300Ets 400Ets 500Ets 600Ets 700

Tabla de contenido