Cleaning, Care & Maintenance
Always switch off the power and disconnect the appliance from the power
supply before cleaning.
Clean the collection tray regularly with warm soapy water.
DO NOT immerse the appliance in water. Wipe the safety guard and external casing with a damp
cloth.
Change the bulbs every 9 months.

Changing the Bulb

WARNING: Always turn Off the appliance and disconnect from the power supply
before changing the bulb.
1. Remove the collection tray.
2. Lay the appliance face down.
3. Unscrew the two screws holding the safety guard at the rear of the Fly Killer.
4. Lift up the guard rail.
5. Holding the ends of the bulb, twist it 'forwards' in its socket until it clicks.
6. Slide the bulb up out of its sockets.
7. Replace with a new bulb.
8. Twist the new bulb 'backwards' to lock it back in place.
9. Replace the guard rail and the two screws.

Troubleshooting

Fault
The appliance is
The unit is not switched on
not working
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Tube has expired
Tube is faulty or has not been fitted
correctly
4
CE893-CE894-CE895_ML_A5_v3_20200528.indb 4
CE893-CE894-CE895_ML_A5_v3_20200528.indb 4
Probable Cause
Solution
Check the unit is plugged in correctly and
switched on
Call EAZYZAP agent or qualified Technician
Replace the plug fuse
Check power supply
Call EAZYZAP agent or qualified technician
Refer to the 'Changing the Bulb' section