6 6
6Safety6Notes
6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The hot and cold supplies must be of equal pressu-
res.
6 14835000: Only dishwashers and washing
machines certified with the DVGW emblem may be
connected to the appliance connection valve without
an additional fuse. If no consumer is connected to
the appliance connection valve, it must be plugged.
Installation6Instructions
• The fitting must be installed, flushed and tested after
the valid norms!
Technical6Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
4
English
Symbol6description
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
Assembly6see6page631
To adjust the hot water limiter on single lever
mixers, please see page 36. No adjustment
is necessary when using a continuous flow
water heater.
Do not use silicone containing acetic acid!
Dimensions6(see page 32)
Flow6diagram6(see page 33)
Spare6parts6(see page 35)
Operation6(see page 34)
Test6certificate6(see page 33)
Cleaning
see enclosed brochure.