Ega Master Aqua Master 79901 Manual De Instrucciones página 15

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Oiler Types Used on or with Our Tools:
Oiler to mount on the machine or connect in the
Setting the oiler: The adjustment screw item 2 is visible after
removing the screw plug item 3. Theoil supply is decreased by
tightening the screw, and by loosening the screw, more oil gets into
the machine. In most cases it is sufficient to tighten or loosen the
¼ or ½ of a turn. When plugged, clean borehole (dia. 2 mm) with
Correct setting; When under pressure and with the filler screw (item
4) open, the oil must bubble slightly.
The fillint lasts for approx. 8 operating hours.
For stationary pneumatic machines and motors, the lubrication is
carried out by lined-up oilers for horizontal or vertical installation.
Setting of oilers: Shut off air supply. Open plug item 3. Loosen
visible lock nut item 5 with a socket wrench.
Using a screw driver turn back the tightened screw plug item 4 by ¼
to ½ of a turn and then lock again. No oil is to get into the borehole
"a" when filling. Close plug item 3 and open the air supply.
Correct setting: A piece of paper held for a short time in front of the
outlet must be coated with oil without drops forming.
Transparent oiler
For installing in permanently equipped workplaces (especially for
type using service units – see accessories list)
The transparent supply containers allow for good checking as well
as for good setting possibility by means of a screw driver via a
set screw with visible dripping. (The set screw is above the lateral
thread connection – turning to the right for less oil; turning to the left
for more oil) The setting (2 to 5 drops per m³/min air consumption) is
to be carried out when air is flowing through, i.e., when the machine
hose line
screw by
wire.
Line oiler
is running.
15

Publicidad

Tabla de contenido
loading

Tabla de contenido