Changing an opening code
3. Configuration of the system (advanced user)
Keep the door opened while changing the configuration.
3.1 Changing an opening code
C
Type in the master code +
C
When the green light is displayed, open the door.
*
C
Door opened, type in master code again +
C
Select one operator (9 possibilities) by typing :
- "0" +
or
- "1" +
or
- "7" +
or
- "8" +
C
Type in the new code +
C
Type in the new code again +
If you wish to modify another setting, go back to point
- An opening code may be made up of 6, 7 or 8 digits.
- You can modify the code even if the operator is not activated.
Nectra Serrure électronique. Version 1.
for master code.
for operator 1.
.
.
.
for operator 7.
for C.I.T. operator.
Orange light
*
and repeat the operations.