HANDLING AND TRANSPORT
The equipment is packed in a wooden box which is suitable for lifting by fork lifts
or transpallette in order to avoid possible damages. The wooden packing can be
recycled, therefore it has to be disposed in the special waste plan for recycling. It is
advisable to use a wooden board for any handling of the cabinet in order to avoid
damages of the structure.
COMPLAINTS
On receipt of the refrigerated equipment verify immediately, by unpacking carefully
the unit, if there are transport damages. In case the unit is damaged in any way, noti-
fy immediately the driver and, within 3 days, the shipping company by registered
letter. Carefully unpack the unit, paying attention so as not to damage it or throw
parts and /or accessories (i.e screws) away. Every complaint must arrive at the
manufacturer within 8 days from receipt of the equipment.
IMPORTANT INSTRUCTIONS AND SUGGESTIONS
Before using the equipment it is important to read these instructions carefully as
improper use can be dangerous. Before connecting the refrigerated unit, make sure
that the power supply voltage is as indicated on the label (fig. C). The equipment
MUST be connected to a grounded power socket, in compliance with the current
legislation to satisfy the safety requirements.
For usage of the unit, as every electrical device, basic rules have to be followed :
- do not touch or plug the equipment with damp or wet hands or feet;
- do not pull the electric cable to unplug it;
- do not expose it to the atmospheric agents;
- do not allow children to use it without adult supervision;
- before starting any cleaning or maintenance operation, it is necessary to
unplug the equipment and do not attempt to make any modification.
WORKING TEMPERATURE
This equipment is manufactured in conformity with the ambient conditions of
climatic class 3 (25° C - 60% R.H.) EN 441 - 4. The refrigerated unit maintains its
performance characteristics with an ambient temperature and relative humidity of
no more than: + 25° C and 60% R.H. (relative humidity). In case the ambient condi-
tions are not included in the above mentioned ones, a lower performance must be
expected.
CLEANING
IMPORTANT - DURING THE WOLE CLEANING OPERATION USE
WORKING GLOVES OF CLASS II TO PROTECT YOUR HANDALL
THE TIME
Before switching on the unit, clean the equipment thoroughly, both inside and outsi-
de including the gasket of the door, using warm water and a solution of bicarbonate
of soda (1 tea spoon every 2 liters) or white vinegar. Carefully dry the unit with a
soft cloth; never use metal pads or abrasive substances. Never use sharp objects;
any damage resulting from the use of these objects will not be covered by warran-
ty.
ELECTRICAL POWER / CONNECTION
First of all, make sure that there is an efficient ground system in compliance with
the current legislation regarding electrical safety.
When in doubt, request a careful check from a qualified technician. The unit is
equiped with the plug and the electrical cable mod. Schuco (fig. D). The necessary
operations are :
1) verify that the power supply voltage is as indicated on the machine rate plate (fig.
C 230 V - 50 H monophase)
2) in case of incompatibility between the socket and the plug of the unit,
the plug should be replaced with a suitable one by a qualified technician
3) do not connect any other appliance to the same power socket
4) do not pull the electrical cable or the unit to unplug the equipment from the
socket (fig. E).
5) Pay attention that the power supply cable is laid in such a way as to prevent it
from being damaged or becoming hazardous to people and things.
THE MAIN POWER SUPPLY LINE CAN BE ALTERED ONLY BY A QUALIFIED
TECHNICIAN.
6) In case the power supply cable is damaged, it should be replaced only by a quali-
fied technician.
INSTALLATION
The refrigerated unit must be installed in a suitable dry place and on a level floor
(Fig. G) to avoid an higher energy consumption and a shorter compressor life.
It must be installed on a level floor to prevent noise, bad working and, during the fit-
ting phase, the problems with alignment of the glass structure holes (on the pistons
version the glasses could not close perfectly or be broken).The refrigerated equip-
ment should never be installed:
a - near sources of heat such as radiators, direct or indirect sunlight or other
equipment which produces heat (fig. F);
b - in line with draughts coming from doors, windows or air conditioning systems (fig. F).
Do not close or obstruct the ventilation openings of the refrigeration unit.