Maintenance
Operation only allowed to qualified person, damages due to
unprofessional operation or remove of any parts inside will
not be considered in warranty service. There are no service-
able parts inside the device or package, service only leaves to
authorized dealers.
Never allow the optical components contact with oil, fat or
any other liquid.
A regular clearance of the device is needed for long-term us-
age, this is very helpful to maintain the lifetime and bright-
ness need to use a soft and lint-free cloth to clean the optical
system, fan and air flowing tunnel.
Trouble Shooting
Problems
Device not power up
Pan/Tilt error or vibrate
LED off
Device not response
to DMX
Replacement of the fuse
Need to replace with same type and rating, which originally
installed in the device.
Step One: Unplug power cable from main power.
Step Two: Unscrew the fuse holder out of the housing
with a screwdriver.
Step Three: Remove the broken fuse and replace with an
exact same type of new fuse.
Step Four: Insert the fuse holder back to the housing and
screw tight and reconnect power.
ION 3715Z
ENGLISH VERSION
Possible reasons
Powercon or power cable
damaged
Faulty power supply
Faulty Pan/Tilt PCB
Faulty opto sensor
Cable loosen
Temperature protection
Fan not working
Faulty LED
Dimmer and strobe set at 0
Faulty power supply
Faulty communication IC
Faulty display PCB
Wrong DMX addressing
Faulty DMX cable
Checking or solutions
Change a good power cable to try
Replace new power supply
Replace PT001 PCB
Replace opto sensor OP001
Check the cable connect to OP001
Check the temperature from menu
Check the fan speed info from menu
Replace new LED
Set dimmer and strobe channel at 255
Replace new power supply
Replace the IC with back-up one in the display PCB
Replace new display PCB
Check the address and setting
Change to a good DMX cable