6.3 Battery replacement
If the battery symbol appears on the LCD accompanied by buzzer alarm,
batteries must be replaced.
Batteries should be replaced as follow:
Remove the screw on the back of the meter and open the battery
Replace the battery compartment cover and secure the compartment
screw.
Warning
1. Do pay attention to the right polarity of battery when putting in or replacing
batteries. In case of polarity reversal, the light meter will be damaged,
2. Neither connects one polarity of the battery to the other one with wire, nor
3. Do not attempt to discompose the battery! The battery's intensively
alkaline electrolyte is corrosive and endangers the user. In case of
contact of the electrolyte with skin or clothes, immediately rinse touched
immediately rinse eyes with clean water and seek medical advice.
Notice
1. The light meter should be turned off before replacing batteries.
2.
3. If the meter is not to be used for a long time, take out the batteries.
4.
recycling, reuse and treatment.
6.4 Calibration Interval
In order to ensure the accuracy of the meter, periodic calibration should
be performed by our debugging personnel. It is recommended to make
calibration every year. If the meter is in frequent use or used in poor
environments, the calibration interval should be accordingly shorten. If the
meter is less used, the calibration interval may prolong to three years
7. Reference Table for Illumination Standard of Various Locations
Fc illuminance value can be got from Lux illumination value divided
by 10.6.
Schools:
illuminance
(Lux)
Drafting classroom, sewing classroom, computer
1500~300
classroom
Classroom, laboratory, practice workshop, research
750~200
conference room, health center, restaurant, kitchen,
pantry, radio room, printing room, switchboard room,
guard room, indoor stadium
Large classroom, auditorium, storage cabinet room,
300~150
lounge, staircase
Corridor, elevator corridor, toilet, duty room, workers
150~75
room, bridge, school outdoor playground
75~30
illuminance
(Lux)
2000~1500
1500~750
punching, typing
Conference room, printing room, switchboard room,
750~300
control room, reception room, recreation room, restaurant
Stack room, entertainment room, dining room, lounge,
300~150
guard room, elevator (passway), washroom, toilet
Tea room, changing room, warehouse, nightwatchmen
150~75
75~30
Fire escape
ELCART DISTRIBUTION SPA via Michelangelo Buonarroti, 46 - 20093 Cologno Monzese (Milano) ITALY
Tel. +39 02.25117310 Fax +39 02.25117610 sito internet: www.elcart.com
La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.
The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product.
La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto.
ELCART
Manuale di istruzioni/Scheda tecnica
Locations
Locations
Factories:
illuminance
(Lux)
Ultra-precision operation, design, drafting, precision
3000~1500
inspection
1500~750
Packaging,
750~300
300~150
Dyeing, casting, electrical room
Entrance and exit, corridor, information channel,
150~75
staircase, dressing room, toilet, operation warehouse
Fire escape, warehouse, outdoor power equipment
75~30
(loading and unloading, inventory move operation)
Hospital:
illuminance
(Lux)
10000~5000
Visual function test chamber (ophthalmology lightroom)
1500~750
Operating room
Consulting room, treatment room, pharmacy room,
prescription room, drug store, dissection room, pathological
750~300
bacteria room, emergency rooms, maternity ward, dean's
Ward, medicine room, bed reading, medicine changing,
300~150
plaster bandage for fractures, infant room, record room,
waiting room, consulting room, outpatient corridor
Locker room, physical therapy room, X-ray room, ward
150~75
corridor, medicine room, sterilization room, ward room,
stairs, endoscopy room
75~30
House:
illuminance
(Lux)
2000~750
Handcraft, tailoring
1000~500
Writing, work
Reading, makeup, kitchen table, processing area,
750~300
telephone
Wash sink, entertainment room, living room, family
300~150
reunion, entrance (inside) mirror
150~70
Wardrobe, bedroom, bathroom, stairs, corridor
75~30
Doorplate, mailbox, doorbell key, terrace
User information ex art. 26 D. 49/2014
The symbol labelled on the appliance (Annex IX D. 49/2014) indicates that
ELCART DISTRIBUTION SPA
Via Michelangelo Buonarroti, 46
20093 COLOGNO MONZESE (MI)
PAGINA 10 DI 15
Locations
measurement,
surface
treatment,
Locations
Locations
ITALY
Made in China
e-mail: info@elcart.it