1. Introduction

1.1 Product description

Outrange indication (When the measured value exceeds the current
range, LCD will display the signal "OL" to indicate that the range is
Auto power-off function (The machine will be powered off automatically
keys are not operated for more than 10 minutes)
Compact design, durable, and portable.

1.2 Name and function of components

1.2.1 Plan view

1. Opto-sensor protection cover
2. Opto-sensor
3. LCD display screen
4. Compound key for main:
Power on/off: Short press the key to activate the machine and long press
for 1 second to shut it down.
Touch tone on/off: Under working mode, short press the key to turn on
and off the touch tone.
5. Max and min values inquiry key
6. Lux/Fc unit conversion key
7. Compound key for data hold and zero calibration:
Data hold: Short press the key to enter/exit data hold mode.
Zero calibration: Long press for 1 second to perform zero calibration
function
8. Compound key for relative value and peak value measurement:
Relative value measurement: Short press the key to enter/exit relative
value measurement mode.
Peak value measurement: Long press for 1 second to enter/exit peak
value measurement mode..
9.
exit manual range switching mode.
ELCART DISTRIBUTION SPA via Michelangelo Buonarroti, 46 - 20093 Cologno Monzese (Milano) ITALY
Tel. +39 02.25117310 Fax +39 02.25117610 sito internet: www.elcart.com
La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.
The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product.
La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto.
ELCART
Manuale di istruzioni/Scheda tecnica

1.2.2 LCD display interface

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.-12. Prompt for max and min values inquiry

2 Measurement methods

2.1 Notices prior to measurement

Warning
1. Do not use the light meter in environments full of dusts or having gas
2. Do not use the light meter for measurement in the place with high
temperature and high humidity.
3. Do not use the light meter in environments with intense infrared or
ultraviolet rays!
Tips
1. The opto-sensor of this meter is designed by simulating the sensitive
curve of light obtained through human eyes. The spectral coverage is
between 320mm and 730mm. When it is used for measurement within
the infrared range, there will be a large data deviation.
2. The opto-sensor is calibrated by common electric incandescent lamp
reading number may be different for the spectrum of other lamps.
3. The reference level of light source test is at the top of the spherical
surface illuminated.
4. The optical detector should expose to light for 2 minutes before
measurement.
5.
should be avoided.

2.2 Action principles

2.2.1 Concepts of illuminance scales

One lux (lumen) indicates the illuminance got on a surface of one square
meter, all points of which are one meter from a uniform source of one
candela.
One foot-candle (Fc) indicates the illuminance got on a surface of one
square foot, all points of which are one foot from a uniform source of one
candela.

2.2.2 Unit conversion for illuminance scales

1 Fc = 10.764 lux
1 lux = 0.09290 Fc

2.2.3 Conversion formula for illuminance and light intensity

E = I / r
During the measurement, the minimum distance between the luminous
surface of light source and the opto-sensor should be more than 15 times
greater than maximum size of the luminous surface (or opto-sensor).
Prompt for manual range switching mode.
Prompt for data hold mode.
The analog bar shows the current measurement value information.
The digit shows the current measurement value information.
Lux unit
FC unit
Prompt for auto measurement mode
Prompt for peak value measurement mode
Prompt for low battery
Prompt for relative value measurement mode
2
I --- Light intensity of the light source(Unit: cd)
r --- Distance from the luminous surface of light source to the
optical detector (Unit: mt.).