ASSEMBLy
 Raise the handle end of the generator high enough to
gain access to the frame bottom; securely position props
underneath to support.
 Insert an axle through the center of the wheel.
 Place a washer on the axle, then slide the axle through
the bracket on the frame.
 Slide the hitch pin through the hole in the axle and make
sure it is secure.
 Repeat the process on the other side to install second
wheel.
CONNECTING BATTERy
See Figure 7.
The battery cables must be connected before the electric
start feature of the generator can be operated.
 Connect the red wire to the positive (+) terminal first,
then connect the black wire to the negative (−) terminal
using the bolts, nuts, and washers provided. Make sure
all connections are tight.
NOTE: Be careful not to short across the terminals when
installing. Shorting the terminals together can cause
sparks, damage to the battery or generator, or even burns
or explosions.
 Cover the terminals with the rubber covers.
When removing the battery for replacement: remove the
nut and bolt first from the negative (black) post, then from
the positive (red) post, being careful not to short across the
terminals. Always abide by the safety warnings provided with
the battery. Remove the battery and dispose of according
to local and state regulations.
WARNING:
To reduce the risk of electrocution or explosion, do
not short circuit the battery terminals or charge in a
sealed container. Keep sparks and flame away.
WARNING:
Keep metal objects away from the battery
terminals. Metal objects can make a connection
from one terminal to another. Shorting the battery
terminals together may cause sparks, burns, or
a fire.

REMOVABLE CONTROL PANEL

See Figure 8.
To detach the removable control panel from the
generator:
 Turn off the generator.
 loosen the latch on the removable control panel and pull
the control panel forward.
 Disconnect the twist-lock plug and the 12V engine control
connector on the back of the control panel.
INSTALLING A WALL MOUNT FOR THE
REMOVABLE CONTROL PANEL
See Figure 9 - 10
The removable control panel can be removed from the
generator and wall-mounted in another location before re-
connecting it to the generator.
To wall-mount the removable control box:
 Screws or nails for hanging the box should be spaced
4-1/4 in. from center to center.
 Mark the 4-1/4 in. measurement on a wall stud or other
sturdy wood surface.
 Drill holes and insert the screws; tighten the screws
securely into the wood. If using nails, the nail head should
be large enough to hold the control panel securely.
NOTE: There should be at least 5/8 in. of the screw or nails
protruding from the wood piece for hanging the box.
 Hang the box on the screws or nails, making certain it is
secure.
12 — English