With a 110 – 240 V~ mains connection, the rectifier automatically switches
from battery to mains operation.
When disconnected from the 110 – 240 V~ mains supply, the rectifier auto-
matically switches back to battery operation. Mains operation via the rectifier
always takes priority over battery operation.
5.1
Control elements
Item
in fig. 1, page 3
1
2
3
4
6
Mounting the mains rectifier
If you wish to mount the mains rectifier in a fixed position, please observe the
following mounting instructions:
NOTICE!
A
Fix the mains rectifier in upright position only. In case you have to
install the rectifier in a different position put the rectifier in a fire
resistant housing to prevent any fire being roused to other objects
by hot plastic tripping through the air slots.
Do not mount the device
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions
Make sure the socket is near the device and is easily accessible.
The place of installation must be well-ventilated. A ventilation system
which is at least equivalent to the air openings in the device must be pre-
sent for installations in closed housings.
The air intake on the underside or the air outlet on the back of the device
must remain clear.
EN
Explanation
Mains cable
Battery input terminals
Compressor output terminals
Fastening holes
Mounting the mains rectifier