Commissioning
GB
7.3 RGTF/RGTKF commissioning
with FE receiver
Tab. 4: Wireless parameter
Prog. no.
120
121
130
131
132
138
38
Set up wireless connection
Note: Carry out the wireless connection with loose components near the FE receiv-
er to ensure that all components are within range.
In order to set up the wireless connection between the FE receiver and RGTF/
RGTKF room controller, the following conditions must be met:
- the FE receiver must be correctly connected at the boiler
- the batteries of the RGTF/RGTKF room controller must be inserted correctly
The wireless connection to the RGTF/RGTKF is established as follows:
1. Hold down the key on the FE receiver until the LEDs
2. At the RGTF/RGTKF room controller, call up the menu option "Wireless" at the
setting level "Commissioning (I)"
3. Select "Binding" (prog. no. 120)
4. Select option "Yes" to start building the connection
For information on changing parameters, see the boiler installation manual.
Note: The status of the connection process will be shown in the display of the
RGTF/RGTKF room controller. Connection has been made when the LED
few times on the FE receiver and then illuminates permanently.
Setting level
Function
Wireless
Binding
C
Yes | No
Test mode
C
Yes | No
Room controller 1
C
Missing | Ready for operation | No reception | Change batter-
ies
Room controller 2
C
Missing | Ready for operation | No reception | Change batter-
ies
Outside sensor
C
Missing | Ready for operation | No reception | Change batter-
ies
Delete all devices
C
Yes | No
Test wireless connection
The wireless connection to the RGTF/RGTKF is tested as follows:
1. Hold down the key on the FE receiver until the LEDs
2. At the RGTF/RGTKF room controller, call up the menu option Wireless at the
setting level Commissioning (C)
3. Select "Test mode" (prog. no. 121)
4. Select option "Yes" to start the connection test
Room device RGT B/RGTK B and RGTF B/RGTKF B
and illuminate
flashes a
Standard value
No
No
Missing
Missing
Missing
No
and illuminate
136231-02 10.15