360 mm
11
9
10
Technical specifi cations
Description
Model
Rated heat load
Water flow
Type of gas
Gas pressure
Water pressure
Ignition
Power
Safety devices
Connections: Gas inlet G1/2" - Cold water inlet G1/2" - Hot water outlet G1/2"
For gas pressure: 1) Standard for Chile — 2) Standard for Colombia
Manual W10804710.indd 23
Manual W10804710.indd 23
1
2
3
5
4
12
6
7
8
Fig. 1b
Automatic gas water heater
WKL71311Q
WKL71321Q
12.1
12.4
kW
kW
6.0 L/min
6.0 L/min
Natural
L.P.G.
1.76 kPa
(1)
2.75 kPa
2.0 kPa
2.9 kPa
(2)
Minimum: 0.02 MPa (2.90 psi) - Maximum: 1 MPa (145 psi)
Water-controlled automatic ignition
———
2 batteries (D 1.5 V)
– – –
•
Flame failure protection.
•
Protection against excessive water pressure.
•
Flame sensor valve: it shuts gas off if there is no flame.
•
Sensor valve for water minimum pressure.
•
Thermostat: it prevents water from exceeding 75 °C.
145 mm
WKL71312Q
WKL71322Q
WKHLWP1101Q
WKL71312Q
WKL71322Q
22.6
kW
12.0 L/min
Natural
(1)
1.76 kPa
(1)
2.0 kPa
(2)
(2)
23
1. Front cover
2. Flame check window
3. Flame level
4. Water flow control
5. Display
6. Battery box
7. Cold water inlet
8. Drain valve
9. Hot water outlet
10. Gas inlet
11. Flame regulador
12. Hot-cold water switch
13. Rear cover
13
WKHLWP1101Q
22
22
kW
kW
12.0 L/min
11.0 L/min
L.P.G.
L.P.G.
2.75 kPa
2.75 kPa
(1)
2.9 kPa
2.9 kPa
(2)
(2)
(1)
25/01/16 09:16
25/01/16 09:16