Installation guide
The gas supply pressure must be adjusted
according to the type of fuel being used:
L.P. Gas to 2.75 kPa to Chile and 2.9 kPa to
Colombia and Natural Gas 1.76 kPa to Chile
and 2.0 kPa to Colombia.
Important:
The distance between the point of use
and the heater should not exceed 10 m.
Assembly
Important:
Make sure there are no spark or fire
sources in the environment when installing
the product.
Drill holes according to Fig. 5. Place
expanding pin in the upper hole and plastic
bushes in the lower holes. Fit the water
heater in upper pin without tilting it and then
fit screws into lower bushes and tighten
them.
266 mm
WKL71311Q
WKL71321Q
Fig. 5
Manual W10804710.indd 25
Manual W10804710.indd 25
218 mm
60 mm
WKL71312Q
WKL71322Q
WKHLWP1101Q
25
Carbon Monoxide poisoning
Hazard
Install the heater strictly according to
the requirement in the manual.
Do not connect a Natural Gas water
heater with L.P gas.
Do not connect a L.P gas water
heater with Natural Gas.
Do not install the water heater in
bedroom, basement, bathroom, or
other rooms under poor ventilation
condition.
The heater must exhaust combustion
gases to outdoors.
The exhaust duct must be installed
by qualified personnel in strict
observance of the installation
instructions.
Examples of qualified personnel are:
gas technicians, authorized personnel
from the gas supplier company,
authorized service personnel.
Failure to follow these instructions
can result in death or carbon
monoxide poisoning.monoxide
poisoning.
Explosion Hazard
Use a new certified gas supply line.
Install a gas shut off valve.
Failure to follow these instructions
may result in death, explosion, or fire.