These instructions are designed for the installation engi-
neer to assemble the product and for the user to operate
and maintain it. After installation, please pass them on to
the user for safekeeping.
Symbols and their meaning
Caution! Warning of personal injury or material damage
Caution! Warning of electric shock.
Caution! Warning of water damage.
Note, tip or reference
Correct assembly/functional test
Incorrect assembly
Observe assembly details
Optional/accessories
Switch on/off
Front and wall lighting
Washbasin lighting
Light colour - daylight white (cool white)
Light colour warm white
Safety Information
– The electrical installations must be undertaken by a
specialist electrical installer in compliance with IEC
60364-7-701/VDE 0100 Part 701! National and local
regulations must be taken into consideration!
– Do not start the appliance if it or the power supply ca-
ble is damaged, but have it replaced by the manufac-
turer, its customer service or by an equally qualifi ed
person.
– It must be ensured that the wall can support the
weight of the mirror cabinet.
To prevent personal injury or material damage the as-
sembly must be carried out by two persons.
Intended use
As a mirror cabinet with dimmable lighting for use in wet
rooms such as bathrooms and toilets.
The product is suitable only for mounting indoors!
Caution! Only install in frost-free rooms.
Important information, please make sure to read!
Declaration of conformity! This product complies with
the requirements of the valid EU Guidelines. The dec-
laration of conformity for this product can be requested
from the following address:
KEUCO GmbH & Co. KG, Oesestraße 36,
D-58675 Hemer.
Technical data
– Supply voltage:
– Max. power consumption:
Prod. No.:
14305 1713X1:
14306 1713X1:
– Protection category:
– Ambient conditions:
Temperature
– Luminous colour
Mounting dimensions, see page 2.
Installation, see fi gure 1 onwards on page 21.
Connection, refer to fi gure 4 on page 22.
Operation
As with a multiway switch, the mirror cabinet cabinet
can be operated with the sensor button A on the mirror
cabinet, or with an external light switch B (installation
type I or III); refer to fi gure 4 on page 22.
Depending on the type of connection, the sockets are
permanently supplied with voltage (I or II) or switch
controlled (III).
KEUCO recommends connection type I in combination
with a switch for switching on/off .
220V-240V AC 50Hz/60Hz
Width
Weight
1200 mm
37.5 kg
1400 mm
42.5 kg
5° – 40° C
2700 – 6500 Kelvin
L
= brown
N
= blue
= green/yellow
L1
= black
A
EN
Light
60.9 W
64.3 W
IP20
B
5