FEATURES
 2 Independent Zones, each with balanced XLR-output (+unbalanced on cinch)
 Each zone has 3band tone controls, balance, volume and mono/stereo switch
 11 inputs on 5 Channels (5 balanced mic + 4line + 2phono)
 1Microphone with 3band tone control and zone assignable adjustable talkover.
 Every Channel can be assigned to zone A, zone B or both.
 Every Channel has individual peak and signal present leds.
 Gain levels and 45mm faders on all channels
 PFL with rotary selector, cue level adjustment and 6.3mm headphones jack.
 2 independent record outputs without Channel1 microphone and free from talkover
muting.

BEFORE USE

CHECK THE CONTENTS:
Check that the carton contains the following items:
 CONTROL5.2 / MIX5.2 Mixer unit
 Operating instructions
 Mains cable
SAFETY INSTRUCTIONS:
CAUTION: To reduce the risk of electric
CAUTION
shock, do not remove any cover. No user-
serviceable parts inside. Refer servicing to
qualified service personnel only.
The lightning flash with arrowhead symbol within the equilateral triangle is
intended to alert the use or the presence of un-insulated "dangerous voltage"
within the product's enclosure that may be of sufficient magnitude to
constitute a risk of electric shock.
The exclamation point within the equilateral triangle is intended to alert the
user to the presence of important operation and maintenance (servicing)
instructions in the literature accompanying this appliance.
This symbol means: indoor use only.
This symbol means: Read instructions.
 To prevent fire or shock hazard, do not expose this appliance to rain or moisture.
 To avoid condensation to be formed inside, allow the unit to adapt to the
surrounding temperatures when bringing it into a warm room after transport.
Condense sometimes prevents the unit from working at full performance or may
even cause damages.
 This unit is for indoor use only.
JB SYSTEMS®
OPERATION MANUAL
1/36
CONTROL5.2 / MIX5.2 MIXER
ENGLISH
 Don't place metal objects or spill liquid inside the unit. No objects filled with liquids,
such as vases, shall be placed on this appliance. Electric shock or malfunction may
result. If a foreign object enters the unit, immediately disconnect the mains power.
 No naked flame sources, such as lighted candles, should be placed on the
appliance.
 Don't cover any ventilation openings as this may result in overheating.
 Prevent use in dusty environments and clean the unit regularly.
 Keep the unit away from children.
 Inexperienced persons should not operate this device.
 Maximum save ambient temperature is 45°C. Don't use this unit at higher ambient
temperatures.
 Minimum distances around the apparatus for sufficient ventilation is 5cm.
 Always unplug the unit when it is not used for a longer time or before you start
servicing.
 The electrical installation should be carried out by qualified personal only, according
to the regulations for electrical and mechanical safety in your country.
 Check that the available voltage is not higher than the one stated on the rear panel
of the unit.
 The socket inlet shall remain operable for disconnection from the mains.
 The power cord should always be in perfect condition: switch the unit immediately
off when the power cord is squashed or damaged.
 Never let the power-cord come into contact with other cables!
 In order to prevent electric shock, do not open the cover. Apart from the mains fuse
there are no user serviceable parts inside.
 Never repair a fuse or bypass the fuse holder. Always replace a damaged fuse
with a fuse of the same type and electrical specifications!
 In the event of serious operating problems, stop using the appliance and contact
your dealer immediately.
 Please use the original packing when the device is to be transported.
 Due to safety reasons it is prohibited to make unauthorized modifications to the
unit.
INSTALLATION GUIDELINES:
 Install the unit in a well-ventilated location where it will not be exposed to high
temperatures or humidity.
 Placing and using the unit for long periods near heat-generating sources such as
amplifiers, spotlights, etc. will affect its performance and may even damage the
unit.
 The unit can be mounted in 19-inch racks. Attach the unit using the 4 screw holes
on the front panel. Be sure to use screws of the appropriate size. (screws not
provided)
Take care to minimize shocks and vibrations during transport.
 When installed in a booth or flight case, please make sure to have good ventilation
to improve heat evacuation of the unit.
 To avoid condensation to be formed inside, allow the unit to adapt to the
surrounding temperatures when bringing it into a warm room after transport.