Ferroli QUADRIFOGLIO B Instrucciones De Uso, Instalación Y Mantenimiento página 71

Ocultar thumbs Ver también para QUADRIFOGLIO B:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

QUADRIFOGLIO B
Plumbing circuit examples
In the examples described below, the checking/change of some parameters may be required.
To do this it is necessary to access the Technician menu.
From the Home page, press the main Menu button (detail 12 - fig. 1).
Access the "Technician" menu by pressing the contextual button 2 (detail 2 - fig. 1).
MENU
UTENTE
TECNICO
Enter the code "4 1 8" with contextual buttons 1 and 2. Confirm each number with the
OK button.
Menù tecnico
Inserire codice:
0
X X
per selezionare
per confermare
Access the Parameters menu by pressing the OK button.
MENU’ PARAMETRI
per confermare
Access the "Configuration Menu" or "System Type Menu" according to the parameter to
be modified as given in each water circuit example.
Menù Configurazione
b
P .
P
o
per confermare
Two direct heating circuits
- Schematic diagram
fig. 33
fig. 34
fig. 35
Menù Tipo Impianto
b
P .
P
o
per confermare
fig. 36
fig. 37
cod. 3541F574 - Rev. 00 - 09/2017
- Electrical connections
After installation, carry out the necessary electrical connections as shown on the wiring diagram.
Then configure the controller as described in the specific section.
1
2
3
4
5
6
7
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
138
72
37 38 39 40 41 42 43 44
Legend
72 Room thermostat 1st zone (direct)
72b Room thermostat 2nd zone (direct)
138 External probe
307 Circulating pump 1st zone (direct)
306 Circulating pump 2nd zone (direct)
I* ISPESL safety devices (When required - not supplied)
To manage sliding temperature it is necessary to purchase the external probe accessory code 013018X0
- Parameters
Each system requires a different parameterisation. Follow the access procedure given
below.
"System Type Menu"
Change parameter P.01 of the "System Type Menu" to 4.
Change parameter P.09 of the "System Type Menu" to 1.
- Optional functions
As well as the electrical connections of the previous figure (required for this system con-
figuration) there are options that do not require settings.
1
2
3
4
5
6
7
L N
302
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
139
37 38 39 40 41 42 43 44
Legend
139 Remote Control: it can be installed in place of 72 to manage the request of the 1st zone (direct)
300 Burner On indication (voltage-free output): the example shows the connection of an hour counter at 230Vac
301 Fault indication (voltage-free contact output): the example shows the connection of a lamp at 230Vac
302 Remote reset input (230Vac): the example shows the connection of a double-pole switch at 230Vac, allowing
the resetting of a block type fault
357 Fault indication (230Vac): the example shows the connection of a lamp at 230Vac
8
9 10 11 12 13 14 15 16 17 18
L
L
N
306
307
72B
N
L
fig. 38
a 1st zone (direct)
b 2nd zone (direct)
M Delivery
RA High Temperature Return
RB Low Temperature Return
8
9 10 11 12 13 14 15 16 17 18
300
301
357
N
L
fig. 39
EN
71