■ SW502 : Air Conditioner Function Settings
(Set this switch based on the functions of the M series connected to this device.)
M series
SW No.
Functions
No. 1
Availability of a heating mode
No. 2
Not in use
No. 3
Not in use
No. 4
Not in use
No. 5
Not in use
No. 6
Not in use
No. 7
Not in use
No. 8
Availability of a fan (Cooling model only)
P/S series
SW No.
Functions
No.1
Cooling only type/Heat pump type
No.2
Auto mode
No.3
No.4
Fan speed
No.5
Vane
No.6
Swing
No.7
Not in use
No.8
Fan mode
* Fan speed 2 step model : An actual fan speed is 2 step though the display of remote controller becomes 4 step or 3 step.

6. Test Run (Check Operations)

■ Interface status monitor

You can check the status of the interface by the LED lamp on the interface unit board.
LED lamp no.
DC 12 V is not being supplied from the
LED521
air conditioner.
Device is not communicating properly
LED522
with the air conditioner.
Device is not communicating properly
LED523
with the MA remote controller.
* Use the table above to check the device operations.
12
OFF
Combined cooler and
heater
Has a fan or mode
OFF
OFF
Heat pump type
Not available
(setting No. 3
disabled)
Available
(unit)
4 speeds
Available
Available
Not available
Lamp off
DC 12 V is being supplied from the air
conditioner.
ON
Cooling unit only
Permanently set to ON.
Permanently set to ON.
Permanently set to ON.
Permanently set to OFF.
Permanently set to OFF.
Permanently set to OFF.
No fan or mode ON
ON
Cooling only type
Set the mode in accordance with the operation
manual for the indoor unit.
Available
Heat pump type : Set to ON.
(setting No. 3
Cooling only type : Set to OFF.
enabled)
Available
Set to OFF.
(remote controller)
3 speeds (2-speed
When operating a 2-speed model with the 3-speed
model set ON)
setting (ON), the MA remote controller display will
indicate 3 fan speeds. The table below shows the
displays and the actual outputs at that time.
Display
Not available
The Vane function of either of indoor unit :
When the function is provided, it is Available (OFF).
When the function is not provided it is Not avail-
able (ON).
Not available
The Swing function of either of indoor unit :
When the function is provided, it is Available (OFF).
When the function is not provided, it is Not avail-
able (ON).
Permanently set to OFF.
Available
Set to ON.
Lamp on
Blinking at approx. 1 second intervals: Device is
communicating normally with the air conditioner.
Blinking at approx. 8 second intervals: Device is com-
municating normally with the MA remote controller.
Comments
Comments
Meaning
Indoor unit output
Low speed
Low speed
Medium speed
High speed
High speed
High speed
Blinking

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido