If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first unit in a DMX chain.
Always connect the output of one unit with the input of the next unit until all units are connected.
At the last unit, you must close the DMX line with a terminating resistor. Take an XLR connector and solder a 120 Ohm resistor
between signal (-) and signal (+) and connect it to the DMX output of the last unit in the line.
This unit can communicate using RDM (Remote Device Management) via DMX512. RDM is a bi-directional communication protocol for use in DMX512
control systems, it is the open standard for DMX512 configuration and status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 line without affecting the existing non-RDM equipment. The system allows a
controller or special RDM controller to send and receive commands from specific fixtures.
The RDM function allows you, for example to remotely set the DMX start address of your fixtures. This is especially useful when the fixture is installed in
an inaccessible location. Each unit has an RDM UID (unique identification number).
This unit has a touchscreen display as well as 4 control buttons. Navigate the menu structure by pressing the buttons on the side of the display, or
touching the desired menu option on the display directly. The touchscreen can be calibrated through the display options in the menu.
Exits from the current menu or function
Navigates upwards through the menu list or increases the numeric
value when in a function
Navigates downwards through the menu list or decreases the
numeric value when in a function
Enables the currently displayed menu or sets the currently
selected value into the selected function
The display and control panel are powered by onboard battery. This gives access to the most important functions in the control panel, including DMX
addressing, when the unit is not connected to AC power. To activate the display when the unit is not connected to power, press and hold the Menu
button for few seconds . The display extinguishes after 60 seconds automatically when no activity.