Insert the motorized feed tubeY" in the pellet hopper "X" and carry out the auger-burner connection in such a way that
the hose "W" is not twisted and/or bent. Respect the distance given in the fig. 7.
Adjust the burner as required by the instruction manual and, in particular, set the parameter u05 on the burner controller
as indicated in the table.
Burner model
Boiler model SFL
Nominal heating capacity
Nominal heat output
Parameter
40
SUN P7 N
SFL 3
kW
24.9
kW
22
u05
2
fig. 7
OK
fig. 8
cod. 3541F710 - Rev. 00 - 05/2017
SFL 4
SFL 5
33.4
41
30
36
5
3
Y
W
X
SUN P N
SUN P12 N
SFL 6
SFL 7
48
55
42
48
4
5