Installation of UV Disinfection System
3. Mount the system to the wall using the supplied clamps. Various connection methods can be used to connect the water
source to the system.
Note:
DO NOT solder connections while attached to the system as this could damage the O-ring seals.
4. Mount the VIQUA ICE controller horizontally to the wall, near the chamber. Ideally place the controller above the reactor
and away from any water connection point, to prevent any water from potentially leaking onto the controller by means of
a leak at a connection point or a "sweating" system. Make sure you allow for a "drip-loop" as shown in
lamp, and power cord, again, to prevent any water from potentially entering the controller.
5. Install the UV lamp. Refer to
6. When all plumbing connections are complete, slowly turn on the water supply and check for leaks. The most likely cause
for leaks is from the O-ring seal. In case of a leak, shut water off, drain cell, remove the retaining nut, wipe the O-ring
and threads. Clean and re-install.
7
A
Figure 3 Disinfection Installation - Vertical and Horizontal
Figure 4 Flow Restrictor
Figure 5 Drip Loop
Section
4.1.
B
Flow
Figure 5
on the