ERROR - MESSAGE DISPLAY
Code n°
Causes
E01
The left counting sensor is broken or dirty
E02
The right counting sensor is broken or dirty
E03
The code disc is dirty or loosen
E04
The hopper sensor is brocken or dirty
E05
The stacker sensor is broken or dirty
E07
Ambient magnetic field is too strong
E07
MG is not workable
E10
Ambient light is too high
E10
UV sensitivity light is too high
E11
The connector of front display is loosen
OPERATION INSTRUCTION
1.Right way to load the currency
Please load currency the machine same as the following steps.
Currency
Photo 3.1.1
2.Hopper adjustement - the
tight procedure to adjust
the Up/Down screw
Due to long transportation or
use, the screw will be loose.
When the counting is not
accurate, it is necessary to
urn the up/down screw
clockwise to increase the
friction.
3.The right procedure to
change the wear and tear parts
When the rubber tongue is
worn out, please flip it and use
the other side.
Solutions
To clean it or change a new one
To clean it or change a new one
To clean it or tight it
To clean it or change a new one
To clean it or change a new one
To lower the ambient magnetic field
To change a new one
To lower the ambient light
To lower the UV light
To tight the connector
Currency
Photo 3.1.2
tighten
loosen
Adjust the up/down screw
Code n°
Problems
The suspicious currency is being
checked out by UV
EE1
The suspicious currency is being
EE2
checked out by MG
The suspicious currency is being
EE3
checked out by IR
- The half currency is being
checked out
EE4
- The left (right) counting sensor is
dirty or brocken
Two pieces currency are counted
EE5
as one/inaccurate counting
The suspicious currency with
EE6
different located magnetic is
being checked out by MG
Slanting currency is being
EE7
checked out
The currency width is smaller than
EE8
30mm
The currency width is longer than
EE9
85mm
Chain currency is being checked
EEA
out
Broken currency is being checked
EEB
out
9
4. Troubleshooting
Note : when counting and detecting is not accurate, please check the
machine as follows :
The power line
cord is connected
well?
No power
The hopper sen-
sor is dirty, please
clean by brush
The power is on,
but no working
Turn the screw
clockwise to
increase the
friction
Wrong counting
Adjust the MG
sensor
Wrong detecting
10
Solutions
Take out the first currency (sus-
picious currency) in the stacker,
then press « RESET » to continue
Take out the first currency (sus-
picious currency) in the stacker,
then press « RESET » to continue
Take out the first currency (sus-
picious currency) in the stacker,
then press « RESET » to continue
- Take out the first currency (sus-
picious currency) in the stacker,
then press « RESET » to continue
- To clean it or change a new one
To tight the adjustable screw
clockwise
Take out the first currency (sus-
picious currency) in the stacker,
then press « RESET » to continue
Take out the first currency (sus-
picious currency) in the stacker,
then press « RESET » to continue
Take out the first currency (sus-
picious currency) in the stacker,
then press « RESET » to continue
Take out the first currency (sus-
picious currency) in the stacker,
then press « RESET » to continue
Take out the first currency (sus-
picious currency) in the stacker,
then press « RESET » to continue
Take out the first currency (sus-
picious currency) in the stacker,
then press « RESET » to continue
The fuse is worn
The power switch
out
is on
Connect the
The belt is too
hopper sens or
loose or too tight,
line well to the
adjust the belt
main board
Counting sensor
The 6 rubber
is dirty, please
wheels are worn
clean it
out, please
replace them
MG is dirty, please
UV sensor is
clean it
broken or dirty,
please clean it or
replace with new
one