8. NiMH Charging

When charging NiMH batteries, the charger is
switched off using the Delta Peak Method.
■ Connect battery terminal with correct polarity
to the charge connector.
■ Initiate charge process by pressing and hold-
ing the start button. The charging process
can be stopped at any time by repeatedly
pressing the start button.
■ During the charging process, total voltage,
charging current and charged capacity are
shown on the LC display on an alternating
basis.
Battery status
1
No charging
2
Charging started
3
Battery charged

9. Balancing Without Charging

1. Use the balancer lead to connect a lithium
battery to the charger via the balancer
connection.
2. Ensure correct polarity and position when
connecting. The black wire of the balancer
lead must be aligned with the arrow mark on
the charger casing.
3. Ensuring correct polarity, now connect the
main power cables of the battery to the con-
nection at the charger (red = + / black = -).
4.
Briefly press the Start button.
5. The battery voltage is shown in the display
during the charging process.
6. Briefly press the Start button again to stop
the balancing process.
14
A4
®
Status LED
LED and battery
type flash green at
0.5 sec intervals
LED constantly
lights green
Beeper sounds for
15 sec LED lights
orange
Battery status
1
Balancing phase
2
End of balancing

10. Fault Signalling

A fault is indicated by the status LED flashing
in the corresponding LED flash sequence, (----)
flashing in the LC display and the beeper sound-
ing at 0.5 second intervals.
After eliminating the cause of fault, the fault code
memory is reset by pressing the Start button.
Cause of fault
1
Input voltage is low-
er than 11 or higher
than 15 Volt
2
Battery connect-
ed with reversed
polarity
3
Main power supply
cable disconnected
during charging
4
Sensor lead dis-
connected during
charging
5
Fault in power
circuit
Status LED
LED flashes orange
at 0.5 sec intervals
LED flashes orange
with number of
cells, beeper
sounds for 15 sec
LED flash se-
quence
1
2
3
5
6